protection against failure of anti-crushing
protective devices according to Category 2 in
compliance with the prescriptions of EN 12453
point 5.1.1.6. It follows that if the safety devices
are not connected or are faulty, operation of the
control unit will be inhibited.
• The device can be used by children no older
than 8 years old and people with reduced
physical, sensory or mental capabilities, or lack
of experience or without the required knowledge,
but only under surveillance or after having
received instructions about the safe use of the
device and the hazards inherent in it. Children
should not play with the device. Cleaning and
maintenance should not be carried out by
children without supervision.
For correct operation of the radio receiver section,
when using two or more control units it is good
practice to install them at a minimum distance of 3
metres from one another.
All operations that require the control unit box to
be opened (connection of cables, programming,
etc.) must be carried out by expert personnel at
the time of installation. For all further operations
that require the box to be re-opened.
IMPORTANT FOR THE USER
• The device must not be use by children or
people with reduced psychophysics abilities, or at
least in case they are supervised or educated on
the operation and its use.
• Do not allow the children to play with the device
and keep them out from the remotes.
• ATTENTION! preserve this manual of instructions
and respect the important safety prescriptions
in it contained. The non-observance of these
prescriptions could provoke damages and serious
accidents.
Examine frequently the plant to notice possible
signs of damage. Don't use the device if an
intervention of reparation is necessary.
10.1 TECHNICAL CHARACTERISTICS
Back-up Battery input:
Flashing light output:
Operator outputs:
Photocells power supply:
Working temperature:
Radio receiver:
Transmitters:
Max TX codes stored in memory:
Board dimensions:
24 V
7A/h max.
24 V
4 W max.
24V
1 x 50 W max.
24V
5 W max.
-20 ÷ 50 °C
433 Mhz
18 Bit or Rolling Code
120 (CODE or PED CODE)
100x105 mm.
10.3 ELECTRICAL CONNECTIONS
CN1:
BATT+24V:
+24V Back-up Battery input
BATT-24V:
–24V Back-up Battery input.
LAMP+24V:
+24V Flashing Light Output.
LAMP-24V:
–24V Flashing Light Output.
MOT1+:
Operator 1 + Output.
MOT1-:
Operator 1 – Output.
CN2:
STOP:
Emergency stop input (NC)
GND:
Common GND input
FOTO+:
Photocells Control and Power Supply (24V
GND:
Photocells Control and Power Supply (GND).
FCC:
Operator Closing Limit Switch Input (NC).
GND:
Common GND input
FCA:
Operator Opening Limit Switch Input (NC).
DS1:
Safety Device Input (NC).
GND:
Common GND input
PP:
Pedestrian Pushbutton open-close command input (NO).
ANT-:
Antenna Ground Input.
ANT+:
Antenna Hot pole input.
CN3:
L:
230 V
line input (phase).
N:
230 V
line input (neutral).
• Connection of the Y power cord.
10.4 FUNCTIONAL CHARACTERISTICS
OPERATION:
When either the remote or the low voltage pushbutton panel are used to
control the barrier, operation is as follows:
the first command opens the barrier until motor time elapses or the arm
reaches its opening limit position; the second command closes the barrier;
if another command is transmitted during the Opening movement, the
control unit disregards the command; if a command is transmitted during
the Closing movement the control unit reverses the movement direction.
AUTOMATIC CLOSING:
The control unit can be set up to close the barrier automatically without
sending any additional commands.
Selection of this type of operation is described in Pause time programming
mode.
EMERGENCY STOP INPUT:
The control unit allows the connection of an emergency stop pushbutton
(NC). Pressing this pushbutton irrespective of the current operating mode
of the control unit will cause barrier movements to stop immediately. An
additional barrier movement command will be valid, provided the emergency
stop input is deactivated and, in any case, the control unit will perform the
barrier opening cycle after preflashing for 5 seconds.
PHOTOCELLS:
Photocells can be powered by and connected to the control unit in
accordance with directive EN 12453.
• Input DS1 (NC)
Tripping of the photocells during opening is disregarded, while during
closing it causes reversal of the direction of movement.
OPENING AND CLOSING LIMIT SWITCHES:
The control unit allows the connection of Opening and Closing limit
switches (NC). Tripping of the limit switches in the associated operating
cycles causes immediate stopping of barrier movement.
ADJUSTMENT OF MOTOR FORCE DURING THE "NORMAL" CYCLE:
The electronic control unit is equipped with a "SPEED" trimmer for
adjustment of Motor Force during the Normal cycle.
Adjustment can be performed in a range of between 50% and 100% of
maximum force during the Normal cycle.
DECELERATION:
The operators deceleration function is used to prevent the moving beam
from slamming at speed into the limit stops at the end of the opening and
closing strokes.
During Operator Time programming (see Main menu) the control unit also
allows programming of deceleration in the desired points (immediately
before full opening and full closing); in addition, using the "DELAY" trimmer
the force intensity can be adjusted during the deceleration phase.