IMPORTANT INSTRUCTIONS
WARNING: When using electrical products, basic precautions should always be followed,
including the following:
DANGER: Risk of electric shock. Grounding is required. Connect only to circuits protected by a
Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD).
WARNING: Risk of electric shock. A qualified service representative and a licensed electrician
must install this product and route all electrical wiring for the product. Improper installation will
create an electrical hazard and may not comply with local building and electrical codes.
WARNING: Risk of electric shock. Disconnect power before performing any maintenance. When
disconnected, the product will no longer be electrically live, which will eliminate the risk of electric
shock.
WARNING: Risk of injury or property damage. Please read all instructions thoroughly before
beginning installation.
NOTICE: Follow all plumbing, electrical and building codes.
NOTICE: Provide generous, unrestricted service access to the valve and interface. This access must be
located immediately next to the valve. Refer to the roughing-in information.
Specifications
Pressures
Maximum Static Pressure
Supply Pressure Differential*
Minimum Flow Rate
Temperatures
Programmable Temperature
Default Temperature at Start-up
Minimum Mixed Temperature
Differential from Hot Supply
Optimum Thermostatic Control Range
Temperature Stability at Recommended
Supply Conditions
Ambient Temperature
Maximum Relative Humidity
Electrical
Electrical Service
User Interface Cable Length (supplied)
* In commercial applications where there is a large difference in hot and cold supply pressures or frequent
fluctuation in either supply line is anticipated, it is strongly recommended that pressure regulators be
installed.
Warranty
KOHLER
Electronic Faucets, Valves and Controls
®
FIVE-YEAR LIMITED WARRANTY
Kohler Co. warrants that its electronic faucets, valves and controls will be free of defects in material and
workmanship during normal residential use for five years from the date the product is installed. This
1043183-5-E
125 psi, 862 kPa, 8.6 bar
Max 5 psi, 34.5 kPa, 0.34 bar (Equal pressures recommended.)
1.6 gal/min (Less than 72 psi dynamic pressure.)
6 l/min (Less than 500 kPa maintaining pressure.)
2.1 gal/min (Greater than 72 psi dynamic pressure.)
8 l/min (Greater than 500 kPa maintaining pressure.)
Max 120°F (49°C) Min 79°F (26°C) Full cold may also be selected.
102°F (39°C)
3.6°F (2°C)
86°F (30°C) to 120°F (49°C)
+/- 1.6°F (1°C)
Greater than 34°F (1°C), Max 104°F (40°C)
95% non-condensing
100-240 VAC, 50-60 Hz, 1.5 A
30' (9.14 m)
2