Clean the Inlet Screens
Disconnect the power and turn off the water supply.
Disconnect and remove the removable pipe segment.
Using a screwdriver, remove the inlet clamp screws.
Remove the inlet clamp.
Remove the adapters from the valve inlets.
Gently pull the check valves from the valve inlets.
Remove the screens from the check valves.
Clean the screens to remove any dirt or debris.
Rinse or replace the check valves and screens.
Reassemble the inlet connections.
Troubleshooting
WARNING: Risk of electric shock. Disconnect power before performing any maintenance. When
disconnected, the product will no longer be electrically live, which will eliminate the risk of electric
shock.
CAUTION: Risk of personal injury. The valve may contain hot water; be careful when draining
any residual water.
NOTICE: Any valve maintenance should be performed by a Kohler Co. Authorized Service
Representative.
1043183-5-E
Inlet Clamp
Check Valve
Screen
Adapter
Union Connection
Removable Pipe Segment
4
Kohler Co.