13. TEMPLATE FOR FIXING THE BOILER TO THE WALL

After deciding the exact location of the boiler, fix the template to the wall.
Connect the system to the gas and water inlets present on the lower bar of the template.
Fit two G3/4 taps (delivery and return) on the central heating circuit; these taps make it possible to carry out important operations on
the system without draining it completely.
If you are either installing the boiler on an existing system or replacing one, as well as the above, fit a settling tank under the boiler on
the system return line in order to collect any deposits and scale circulating in the system after flushing.
After fixing the boiler to the template, connect the flue and air ducts, supplied as accessories, as described in the following sections.
If natural draught boilers are installed, connect them to the flue with a metal pipe resistant to normal mechanical stress, heat, products
of combustion and relative condensate.
drain outlet with concentric curve
Drill holes with a Ø 12 bit and insert the supplied rawplugs and supports
BOILER WIDTH 600
Figure 5
240/40 Fi -240/60 Fi - 280/60 Fi
Figure 6
INSTRUCTIONS FOR FITTERS

14. DIMENSIONS OF BOILER

39
1: G 1/2 DHW outlet
2: G 1/2 cold domestic water inlet
3: G 3/4 heating return
4: G 3/4 heating delivery
5: G 3/4 gas inlet to boiler
240/40 i -240/60 i - 280/60 i
926.008.2 - EN