Maintenance
Make sure that the pump is disconnected
from the electric power supply before
performing any maintenance.
If pump performance drops it may be
because the two filters in the kit have
become clogged, and require cleaning.
K
Regularly check the coarse filter on the end
of the suction hose, and clean if required.
After checking or cleaning the pump,
reprime, see steps F-J.
Regularly check fine filter fitted prior to the
pump, and clean if required.
L
Use the large plastic spanner supplied to
loosen large yellow locking nut.
M
Remove cup and filter, clean under a tap. Do
Problem
The pump does not
pump water and the
motor is not running
The pump supplies a
limited amount of
water or the pump
does not pump
water, and the
motor is running,
even after several
minutes the pump is
still noisy
The pump works
only intermittently

Troubleshooting

Possible Cause
No electricity
Plug inserted incorrectly
Circuit breaker is tripped
Damaged motor
Pump has overheated
Pump full of air
Pump is not primed
Obstructed inlet
Obstructed pipe/outlet
Worn impeller
The temperature of the fluid
is too high
Fluid too dirty
not scrub.
Reassemble, and make sure the nut is
tightened securely - use spanner provided.

Pump storage

Disconnect hose and loosen bottom red nut
and allow to drain.
Store the pump in a dry place and protect
from frost.

Contact details

Hozelock Limited
Midpoint Park, Birmingham. B76 1AB
Tel : +44 (0) 121 313 1122
Internet : www.hozelock.com
Email : info@hozelock.com
Remedy
Check that the electricity supply is turned
on and that the pump is correctly plugged
in
Reset electricity supply.
If the circuit breaker trips once more
contact a specialised electrician
Contact Hozelock customer services for
assistance
Pump contains thermal protection - check
if pump case is hot, and if so, allow to
cool
Unplug from the electricity supply
Repeat priming process - follow steps 6 -
10
Check inlet is under surface of water, inlet
filter is clean, and inlet hose is not kinked
or damaged
Remove obstructions in inlet hose or kinks
Contact Hozelock customer services for
assistance
Only use with fluids below 35ºC
Empty and clean the water butt, refill