Safety cut-out
If the battery does not reach a predefined voltage level within a given period, the charger
switches off. Please refer to „Technical data" for the length of time it takes before the
safety cut-out trips.
What to do in the case of a safety cut-out:
1. Unplug the charger from the mains
2. Disconnect battery connection
3. Determine cause of trip
4. Rectify fault and restart charging if necessary
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Wall mounting
Acctiva Easy
0510 955 600
Battery too large
Restart charging
Active accessories using too much power
Switch off accessories and restart charging
Faulty battery (e.g. cell short circuit, smell of gas, differing cell temperatu-
res, housing deforming, different liquid levels or liquid leaking, etc.)
Have battery checked. On no account allow charging to continue
Selector switch incorrectly set
Correct selector switch setting and restart charging
Incorrect charger type for this application
Have battery and charger checked and synchronised