Troubleshooting

General faults
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Errors in test
Before the open circuit voltage test, nothing appears on the display
mode
After establishing the battery connection, not all display elements are activated
Cause:
Remedy:
Cause:
Remedy:
Startability not displayed
After the startability test, the charger changes over immediately to the alternator test
Cause:
Remedy:
Errors during
Charger switches off during charging
charging
Cause:
Remedy:
Charger leads not connected to correct poles
Connect battery poles correctly
Battery open circuit/contact fault
Check charger leads, contacts and battery poles
Charger lead short circuit
Check charger leads, contacts and battery poles for short circuit
Battery is flat/in deep discharge
Charge a deep-discharge battery
Charger leads not connected to correct poles
Connect battery poles correctly
Very good battery and/or very high ambient temperature
System in very good condition. No remedial action necessary.
High ambient temperature. Charger overheating.
Allow charger to cool down. Charging will recommence automatically once
the charger has cooled sufficiently