2. Turn the gear selector while at the same time manually turning the core bit into the recommended
position.
6.6
Activate/deactivate continuous running lock
Never use continuous running lock in handheld operation!
1. Press and hold down the on/off switch.
2. Press and hold down the continuous running lock.
3. Release the on/off switch.
4. Release the continuous running lock.
To deactivate the continuous running lock again, press the on/off switch until the continuous
running lock jumps back to its initial position.
6.7
Operating portable residual current device (PRCD)
WARNING
Risk of injury due to electric shock! Do not continue operating the diamond core drilling machine if the
indicator on the ground fault circuit interrupter does not go out when the 0 or the TEST button is pressed.
▶ Have your diamond core drilling machine repaired by Hilti Service.
1. Plug the diamond core drilling machine's mains plug into an earthed/grounded power outlet.
2. Press the "I" or "RESET" button on the portable residual current device (PRCD).
▶ The indicator lights up.
3. Press the "0" or "TEST" button on the portable residual current device (PRCD).
▶ The indicator goes out.
4. Press the "I" or "RESET" button on the portable residual current device (PRCD).
▶ The indicator lights up.
6.8
Use of the two-part hole-starting aid
CAUTION
Risk of injury caused by incorrect use! Parts can come off the hole-starting aid if it is not pressed against
the work surface.
▶ When a two-part hole-starting aid is used, do not run the diamond core drilling machine without the
hole-starting aid pressed against the work surface.
A different hole-starting aid is required for each core bit diameter.
1. Fit the hole-starting aid into the open end of the diamond core bit.
2. When you start drilling apply only light pressure until the core bit has centered itself. Then apply more
pressure. Drill a guide cut 3-5 mm deep.
3. Release the on/off switch to stop the machine. Wait until the core bit comes to a complete stop.
4. Remove the hole-starting aid from the core bit.
5. Position the core bit in the guide cut, press the on/off switch and resume drilling.
6.9
Dry drilling with vacuum cleaner via built-in power outlet for electric devices
Use slotted core bits only when working without a dust removal system.
1. Secure the side handle in the desired position.
2. Optional: Fit and use the two-part hole-starting aid. → page 49
3. Plug the diamond core drilling machine's supply cord into the power outlet of the vacuum extractor.
*2204400*
2204400
English
49