FUNCTION SELECTION VIA DIP-SWITCH SW1
DIP
ON
1
CONDOMINIUM program
2
STEP-BY-STEP program (*)
(Only with DIP1 OFF)
DECELERATION phase in the last seconds of each
3
manoeuvre (*)
4
Water Hammer enable to facilitate electric lock release
5
TIME PROGRAMMING
6
PHOTOCELL input disabled (terminals 1-4) (*)
(*) DEFAULT SETTINGS
WARNING:
With DIP2 OFF: should the power fail during opening, closing or pause, when the power is restored the control unit automatically performs a full
closing manoeuvre of the gate.
The following table shows what occurs each time a START COMMAND is given depending on the program selected and the state in which
the gate is at that moment.
The gate is
PROGRAM
selected
CLOSED
STEP-BY-STEP
OPENS
RESIDENTIAL
OPENS
CONDOMINIUM
OPENS
ADJUSTING THE TRIMMERS PT1 (motor 1) and PT2 (motor 2)
Turning the trimmers clockwise increases the AMPEROMETRIC LOCKING THRESHOLD of the respective motor (2.5 to 5.5 A).
The intervention of the current limiter both during opening and closing causes an immediate stop of the movement.
DEFAULT SETTINGS: trimmers adjusted to half their stroke.
WARNING !
To facilitate the PROGRAMMING phase, let the control unit or the receiver learn a remote control (see CODE LEARNING), otherwise the START
command must be given by closing the contact to the terminals 3-4.
Start programming from the condition in which the GATE IS COMPLETELY CLOSED.
To enable deceleration set DIP3 to ON before starting to program.
TIME PROGRAMMING
(run time, pause time, gate phase shift time, pedestrian cycle)
1) GATE CLOSED: set DIP5 to ON.
2) Press START: Wing 1 starts opening and after 2 seconds also Wing 2.
3) When Wing 1 arrives against the mechanical stop, it stops automatically. WING 1 STOPS.
4) When Wing 2 arrives against the mechanical stop, it stops automatically. WING 2 STOPS.
5) The flashlight goes off and counting of the pause time starts. After the desired time (max. 240 s) press START: WING 2 STARTS CLOSING.
6) Wait for the time necessar y to assure the desired gate phase shift and then press START: WING 1 STARTS CLOSING.
7) The control unit does not accept any more commands until the WINGS HAVE STOPPED against the respective mechanical closing stops.
7)
GATE CLOSED.
8) Set DIP5 to OFF to finish programming.
If the control unit is coupled to the receiver code AU01780 it is also possible to control partial opening of only WING 1 (pedestrian cycle) using
the 2nd channel of the remote control (previously stored).
To program the PEDESTRIAN CYCLE operate as described above (steps 1, 2, 3, 5, 6, 7, 8), but give the command through the 2nd CHANNEL of
the remote control.
PROFESSIONAL AUTOMATIC SYSTEM FOR GATES AND GARAGEDOORS
The gate is
OPENING
STOPS
STOPS and enables
counting of the pause
time for the next
automatic reclosing
IGNORED
– double swing gates
8
OFF
Uninfluential (see DIP2) (*)
RESIDENTIAL program
(step-by-step with automatic reclosing)
DECELERATION disabled
Water Hammer disabled (*)
Normal operation (*)
PHOTOCELL input enabled
The gate is
The gate is
OPEN
CLOSING
CLOSES
STOPS
CLOSES
(the gate would close
STOPS AND RE-OPENS
automatically at the end
of the pause time)
Reinitialises counting of
the pause time at the
STOPS AND RE-OPENS
end of which it closes
automatically