4.
See
Figure
9. Disconnect and remove the mixer (F) to
expose the breather hose (G).
NOTE: The lower mixer screw is accessible through a hole in
the engine divider panel. Remove the plastic cover from the
hole and set aside for reassembly.
A
F
G
Figure 9. Disconnecting the Mixer
5.
See
Figure
10. Wrap the breather heater (H) around the
breather hose, evenly spaced as shown, with the lead
wires at the bottom. Once installed, wrap the breather
heater and hose with silicone tape (provided) to secure
heater.
A
J
Figure 10. Wrapping the Breather Hose (11–22 kW)
6.
Pass the lead wires through the harness grommet (J) in the
engine divider panel.
Breather Heater Kit
H
7.
See
Figure
the lead wires through the customer connection panel
grommet (K). Secure all wires with plastic wire ties at least
0.5 in. (1 cm) away from fuel hoses.
Figure 11. Lead Wires to Customer Connection (11–22 kW)
002767
8.
Install the mixer and snorkel.
9.
Assemble the airbox.
10. Proceed to

Connecting Lead Wires

2016-Present Units—
See
Figure
12. Connect the heater lead wires to the T1
terminal and Neutral stud as shown.
002768
Figure 12. Input Sense Terminal Block
NOTE: Wire with ring terminal connects to Neutral bar stud.
11. Working inside the intake enclosure, route
K
J
Connecting Lead
Wires.