A. Operating instructions
Please refer to the technical drawings
on page 2 for more information.
Functions
The AD-series are combined units
that will both clean and dehumidi-
fy the indoor air. The air purifying
function is always active as long
as the unit is running. Activate the
dehumidification to remove excess
moisture. When dehumidification is
active the compressor starts and the
icon is lit. When the set humidity level
is reached, the icon is flashing.
Modes
The unit has 4 different modes;
manual, automatic, quiet, or clothes
dry mode (clothes dry mode is only
available when dehumidifying).
Manual mode
Set fan speed manually. Choose
between 4 fan speeds in dehumidifi-
cation mode and 5 fan speeds in air
purification mode. If dehumidification
is activated, set desired humidity
level manually.
Quiet mode
The unit works on the lowest fan
speed. The air quality indicator is
shut off.
Clothes dry mode
(dehumidification only).
Use this function for the quickest
drying of clothes and laundry. The
unit will work on maximum fan speed
continuously; humidity level and fan
speed cannot be set.
Automatic mode
In air purification mode, the fan
speed is set automatically depending
on the air quality of the room. The air
quality is indicated by the light on the
front of the unit;
• Green: no pollution detected.
Fan works on speed 1.
• Blue: light pollution detected.
Fan works on speed 2.
• Yellow: moderate pollution
detected. Fan works on speed 3.
• Purple: heavy pollution detected.
Fan works on speed 4.
• Red: very heavy pollution detected.
Fan works on speed 5.
English
If dehumidification is activated the
unit automatically sets fan speed ac-
cording to ambient relative humidity:
• 60% RH or below: dehumidification
stops, the fan runs on speed 1
• 60-65% RH: fan runs on speed 2
• 66-70% RH: fan runs on speed 3
• 71% RH or above: fan runs on
speed 4
Set desired humidity level
When the set humidity level is
reached the unit stops automatically.
The set humidity level is shown for
a few seconds in the display. CO
means the unit will run continuously,
regardless of ambient humidity.
Set timer for shut off
Set time for automatic shut-off
between 1 and 12 hours. Press the
timer button repeatedly until the timer
display is blank to deactivate. After
the set time has passed the unit is
shut off. To restart it, you need to
manually press the Power button.
Select fan speed
There are 4 fan speeds for dehumidi-
fication and 5 fan speeds for air pu-
rification. A higher fan speed means
quicker air cleaning and dehumidifi-
cation. During dehumidification, when
the set humidity level is reached,
both the compressor and the fan
motor stop for 60 minutes.
After 60 minutes, the fan will start
and run for 3 minutes to sense the
surrounding moisture level. If the
humidity level has not increased, the
machine will continue to stand still for
60 minutes and then start the fan for
3 minutes.
If it is higher than the set limit, both
the compressor and motor will start
again.
Child lock
Press and hold the child lock button
for 3 seconds to activate or deacti-
vate the child lock. When activated,
all buttons are locked.
Show room temperature
Press and hold the mode button to
display room temperature. When
released, the display will return to
showing ambient humidity level.
13
B. Security functions
Automatic shut off function
As a security function, the unit au-
tomatically shuts off if no button has
been touched for 12 hours. Press
any button to reset the 12-hour
countdown.
To deactivate this function, press and
hold the timer button and child lock
button simultaneously for 5 seconds.
The water full indicator flashes and
a buzzer is heard when the function
is deactivated. Repeat this action to
reactivate the function.
Compressor protection
(dehumidification only)
When shut off, the compressor has a
5-minute delay function before star-
ting again to protect the compressor.
Shut off at low or high temperature
(dehumidification only)
When the temperature is below 3°C
or above 40°C the unit will automati-
cally stop dehumidifying and only the
fan will run. The unit will restart dehu-
midification when the temperature is
within the range of 5°C to 38°C.
Low humidity function
(dehumidification only)
When the ambient humidity level is
30% or lower, the display shows LO
and the compressor shuts off. It will
resume when the ambient humidity
is 32% or above. When the ambient
humidity is above 91% the display
shows HI (the unit will run as normal).
Water overflow protection
(dehumidification only)
When the water bucket is full, the unit
stops, the water full icon flashes, and
a buzzer is heard. Empty the water
bucket to restart the unit (see the
section about the water bucket)
Overheat protection
(dehumidification only)
When the unit is dehumidifying at
high room temperature and ambient
humidity level, the fan speed may
automatically be increased to pre-
vent the unit from over-heating. The
fan speed will be restored to the set
value when the ambient humidity
level decreases.