Safety Notes; Installation Instructions; Technical Data; Symbol Description - Hansgrohe PuraVida Instrucciones De Montaje

Ocultar thumbs Ver también para PuraVida:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 6

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
Do not allow the streams of the shower touch
sensitive body parts (such as your eyes). An
adequate distance must be kept between the shower
and you.
The product may not be used as a holding handle. A
separate handle must be installed.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
Shower hoses are only suitable for a connection from
the shower to the fitting. Never fit a shut-off device
between the fitting and the hose.

Installation Instructions

• Prior to installation, inspect the product for transport
damages.After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms.
• Where the contractor mounts the product, he should
ensure that the entire area of the wall to which the
mounting plate is to be fitted, is flat (no projecting
joints or tiles sticking out), that the structure of the wall
is suitable for the installation of the product and has
no weak points. The enclosed screws and dowels
are only suitable for concrete. For another wall
constructions the manufacturer's indications of the
dowel manufacturer have to be taken into account.
• The wall bar must be mounted stress relieved!
• Optimal functioning is only guaranteed with the
combination of Hansgrohe hand showers and
Hansgrohe shower hoses. Shower hoses are only
suitable for a connection from the shower to the fitting.
Never fit a shut-off device between the fitting and the
hose.
4
English
• The premounted filter insert must be used to ensure
a normal flow of the shower and to prevent dirt from
entering through the pipes. Dirt entering can affect
the function and/or lead to damages to the shower.
Hansgrohe will not be held liable for this type of
damage.

Technical Data

Operating pressure:
Recommended operating pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!

Symbol description

Assembly see page 32
Do not use silicone containing acetic acid!
With the excentric washer it is possible to
equalize tolerance of the drilling. (see page
33)
Dimensions (see page 34)

Flow diagram

(see page 35)
Operation (see page 36)
Cleaning (see page 31)
and enclosed brochure
Spare parts (see page 38)
Special accessories (order as an
extra)
corner fitting set #28694000
Test certificate (see page 40)
max. 0,6 MPa
0,15 - 0,4 MPa
max. 60°C
max. 70°C / 4 min

Publicidad

Tabla de contenido
loading

Tabla de contenido