• OUTPUTS:
There are 2 double contact (N.O. and N.C.) relay outputs available (RL1 - RL2)
at the terminal (J10).
The maximum current that can be connected to the contacts is 10A at 250 Vac.
!
WARNING !!
Place a suitably rated protective device (e.g. a fuse), between the relay con-
tacts and the load and which anyway does not exceed a maximum of 10A.
• INPUTS
There are 3 inputs available at the terminal (J14), which can be activated by
connecting them to GND via a "volt free contact" (e.g. a relay).
The inputs will be configured automatically according to the configuration of
the device (see table):
Configuration
Reading point
Pedestrian Passage
Vehicle Access
Bi-directional Vehicle Access
Door manager
Reading point connection example
Door Controller
IN1
Configurable
Configurable
Presence Reader A
Presence Reader A
Door state
22
IN2
Configurable
Transit
Transit
Transit
Presence reader B
Door opener
Door
Controller
XKPR
5
IN3
Configurable
Configurable
Configurable
Configurable
532226 - Rev. D