7.4
Indication for contamination during run mode
8022178.1BXO /2021-05-26 | SICK
Subject to change without notice
Table 16: Index 238
ISDU
Index
Name
Sub-
Index
DEC
HEX
0xE
238
-
Conveyor blanking
E
Figure 24: A = Level 1
Figure 26: A = Level 3
Conveyor belt
1
NOTE
You can find videos on the Reflex Array product page www.sick.com/reflex-array under
"Videos".
Table 17: Indication for contamination
no contamination:
→ continue to set up / use
sensor
Data
Default
Length
Access
type
value
Uint
8 Bit
rw
0
A
1
Figure 25: A = Level 2
A
1
Figure 27: A = Level 4
a little contamination:
→ sensor will still perform;
however, for optimal per‐
formance, clean front lens,
check alignment and dam‐
age of reflector too.
O P E R A T I N G I N S T R U C T I O N S | RAY26
7
COMMISSIONING
Value/Range
0 = Deactivated
1 = Level 1
2 = Level 2
3 = Level 3
4 = Level 4
A
1
A
1
contamination:
→ please clean front lens
of RAY26 and reflector,
check alignment and dam‐
age of reflector too.
A new teach of RAY26 is
not required.
33