English; Temperature Range - i.safe MOBILE IS120.1 Manual Del Usuario

Ocultar thumbs Ver también para IS120.1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 7

ENGLISH

EX MARKINGS
ATEX:
II 2G Ex ib IIC T4 Gb
II 2D Ex ib IIIC T135°C Db
EU Type Examination Certificate:
EPS 21 ATEX 1 107 X
CE-designation:
2004
IECEx:
Ex ib IIC T4 Gb
Ex ib IIIC T135°C Db
IECEx Certificate: IECEx EPS 21 .0040X
EX-RELEVANT SAFETY REGULATIONS
Use of this device assumes that the operator observes the conventional safety regulations and
has read and understood Operating Manual, Safety Instructions and certificate . When used in
explosion hazardous areas, the following Safety Instructions must also be complied with:
Inside explosion hazardous areas the covers of all interfaces (USB) must be closed .
To ensure the IP-protection, it has to be ensured that the all gaskets are present and functi-
onal . There must be no large gap between the two halves of the housing and between the
battery compartment cover and housing .
The device may only be charged outside explosion hazardous areas using the i .safe PROTEC-
TOR 1 .0 Micro USB Cable or other equipment approved by i .safe MOBILE GmbH .
The device may only be charged at temperatures between +5 °C to +35 °C .
Physical connections to to IS120 . 1 are only allowed outside explosion hazardous areas using
the i .safe PROTECTOR 1 .0 Micro USB Cable or other equipment approved by i .safe MOBILE
GmbH .
The device may not be exposed to any aggressive acids or alkalis .
The device may only be used in zones 1 or 21 .
INFORMATION CONCERNING SAR CERTIFICATION
(SPECIFIC ABSORBATION RATE)
The SAR limit of Europe is 2,0 W/kg for the head and body, 4,0 W/kg for the limbs . The device
has been tested against this SAR limit . The highest SAR value reported under this standard
during product certification for use at the ear is 0,72 W/kg and when correctly worn on the
body is 1,44 W/kg, limbs is 3,08 W/kg .
This device was tested for typical body worn operations with the back of the handset kept 5
mm from the body . The device complies with RF specifications when used at 5 mm from the
body . Belt clips, holsters and similar accessories used should not contain metallic components
in the assembly . The use of accessories that do not satisfy these requirements may not comply
with RF exposure requirements, and should be avoided .

Temperature range:

-20°C ... +60°C (EN/IEC 60079-0)
-10°C ... +50°C (EN/IEC 62368-1)
Manufactured by:
i.safe MOBILE GmbH
i_Park Tauberfranken 10
97922 Lauda-Koenigshofen
Germany