Troubleshooting (cont.)
Faucet Troubleshooting Table
Symptoms
2.
Low water flow.
3.
Poor spray
pattern.
4.
Power LED is not
lit.
5.
Water drips or
trickles when
faucet is not in
use.
1387795-2-B
Probable Causes
Recommended Action
C. The hot
C. Confirm that the
and/or cold
supply hoses are not
supply hose
kinked or twisted. If
is kinked or
coiled, maintain an ID
twisted.
of 3" (76 mm).
D. The outlet
D. Confirm that the
hose is
solenoid valve is
kinked.
located within 7" (178
mm) to 8" (203 mm) of
the faucet centerline.
E. One or more
E. Refer to the "Cleaning
screens are
the Screens" section.
clogged.
F.
Cracked
F.
Replace the solenoid
diaphragm.
valve assembly.
A. The spray
A. Rub your finger over
nozzles are
the nozzles with water
clogged.
running to dislodge
debris.
A. No power to
A. Check the power
the circuit
supply connections to
board.
the circuit board.
B. Power cord is
B. Plug the power cord
plugged into
into an unswitched 120
a switched
VAC outlet (test the
outlet.
outlet with a radio or
other device). Confirm
that the power LED
illuminates.
A. Manual
A. Turn the manual
override is
override clockwise until
partially
it stops; then turn it
engaged.
counterclockwise until
the water drip stops.
18
Kohler Co.