Mimic panel
botton 0/1: to turn on and off (hold down for 2") and to exit from the menu during programming
Pressing it brie y allows you to view the SET temperature; holding it down (pressed for 2") allows you to access
various programming menus.
to increase the various settings
to decrease the various settings
(pellet loading/reserve button)
press once to 'inform' the thermal stove memory that a 15 kg sack of pellets has been loaded, thereby allowing it to
keep track of the reserve.
Boiler button: by pressing the boiler button you can access the temperature settings of an outside boiler/accumulator
and change its SET values with the +/- buttons.
To obtain the adjustment it is necessary to connect the special probe (cod.648690), which enables display of the
boiler temperature in real time.
50
60
65
70
Filling the feed screw
If the pellet storage tank is completely emptied, it follows that
the Archimedes' screw is also emptied.
Before restarting the stove you must ll it by following these
steps: press the +/- keys simultaneously (via the remote control
or the synoptic panel) for a few seconds, after which, having
released the keys, the display will show the text "Reload".
It is quite normal for some pellet residue to remain inside the
hopper, this is what the feed screw is unable to pick up.
Once a month, fully vacuum the hopper to prevent dusty resi-
due from accumulating.
Automatic ignition
With the boiler-stove on stand-by, press the 0/1 button for 2
seconds (on the synoptic panel or remote control).
This will start-up the ignition process, 'Start-up' will appear on
the display and a countdown will commence in seconds (1020).
There is no preset time for the ignition process: its duration
will be automatically shortened if the control board detects that
certain tests have been carried out positively.
The ame appears after about 5 minutes.
INSTRUCTIONS FOR USE
Tap the LED points to select a preset temperature of 50°, 60°, 65°, 70°, or 80°; for different
temperature settings, press the SET button to change values using the +/- buttons.
80
Manual ignition (in case of start up failure)
At a temperature lower than 3 °C – too low for the electrical
resistance to become red hot - or if the resistance is temporarily
not working, you can use a relighter to ignite the boiler-stove.
Insert a well-lit relighter into the combustion chamber, close
the door and press 0/1 on the synoptic panel or remote control.
Operating modes
Operating from synoptic panel/remote control.
With the boiler-stove running or on stand-by, from the synoptic
panel.
Press the + or – keys to increase or decrease the desired water
temperature.
- By pressing the BOILER key you can change the SET tempe-
rature of the boiler or of the secondary circuit in general, using
the +/- keys.
It is possible to visualise (if the boiler probe is connected) the
temperature of any boiler/external storage, by pressing the
"boiler" key the set value is displayed, by pressing the +/- keys
while viewing the boiler value set that setting can be varied.
If the boiler probe is not connected dashes appear in place of
the temperature (--.-° C).
- 36
-