11. Specifications
IP ingress protection per IEC/EN 60529
First index number
Degrees of protection against solid foreign bodies (defined by the 1st index number)
5
6
Degrees of protection against water (defined by the 2nd index number)
4
5
6
7
1)
8
1)
1) Ingress protections, describing temporary or permanent immersion, on request
Standard ingress protection of model Tx10-0 is IP65.
The specified degrees of protection apply under the following conditions:
Use of a suitable thermowell (without suitable thermowell: IP40)
■
Use of a suitable cable gland
■
Use of a cable cross-section appropriate for the gland or select the appropriate cable
■
gland for the available cable
Adhere to the tightening torques for all threaded connections
■
11.1 Model TR10-0
Measuring element
Type of measuring element Pt100, Pt1000
Measuring current
Validity limits of the class accuracy in accordance with EN 60751
Class B
Class A
2)
Class AA
2)
1) Pt1000 only available as a thin-film measuring resistor
2) Not with 2-wire connection method
For further specifications see WIKA data sheet TE 61.01 and the order documentation.
WIKA operating instructions models TR10-0, TC10-0 (FM, CSA)
Degree of protection / Short description
Dust-protected
Dust-tight
Protected against splash water
Protected against water jets
Protected against strong water jets
Protected against the effects of temporary
immersion in water
Protected against the effects of permanent
immersion in water
1)
0.1 ... 1.0 mA
Wire-wound
-196 ... +600 °C [-321 ... +1,112 °F]
Thin-film
-50 ... +500 °C [-58 ... +932 °F]
Wire-wound
-100 ... +450 °C [-148 ... +842 °F]
Thin-film
-30 ... +300 °C [-22 ... +572 °F]
Wire-wound
-50 ... +250 °C [-58 ... +482 °F]
Thin-film
0 ... 150 °C [-32 ... +302 °F]
Test parameters
Per IEC/EN 60529
Per IEC/EN 60529
Per IEC/EN 60529
Per IEC/EN 60529
Per IEC/EN 60529
Per IEC/EN 60529
As agreed upon