10. Install a sediment trap at the gas valve inlet to prevent
foreign materials (pipe compound, pipe chips and
scale) from entering the gas valve. Debris blown into
the gas valve may cause that valve to malfunction
resulting in a serious gas leak that could result in a
possible fire or explosion causing loss of products,
building or even life. A properly installed sediment
trap will keep foreign materials from entering the gas
valve and protect the safe functioning of that important
safety component.
11. Any heater connected to a piping system must
have an accessible, approved manual shut off valve
installed within six feet (6 ft.) of the heater it serves.
12. Install the proper size of gas supply line to assure
proper functioning of the heaters. Consult your fuel
gas supplier, or the L.B. White Co., LLC for proper line
sizing and installation.
13. Light according to instructions on heater or within
Owner's Manual.
14. The heater is designed for L.P. vapor withdrawal or
natural gas only. Do not use this heater in a propane
liquid withdrawal system. Do not permit propane in
liquid form to enter the heater.
15. The corrosive atmosphere present in animal confine-
ment buildings can cause component failure or
heater malfunction. The heater should be periodically
inspected and cleaned in accordance with the Mainte-
nance and Cleaning Instructions in this manual. Make
sure that livestock is protected by a back up alarm
system that limits high and low temperatures and also
activates appropriate alarms.
16. Take time to understand how to operate and maintain
the heater using the owner's manual. Make sure you
know how to shut off the gas supply to the building
and to the heater. Contact your gas supplier if you
have any questions.
17. Any defects found in performing any of the service
procedures must be eliminated and defective parts
replaced immediately. Retest the heater before placing
it back into service.
18. Do not exceed input rating stamped on the dataplate
of the heater. Do not exceed the burner manifold
pressure stated on the dataplate. Do not use an orifice
size different than specified for the specific input rating
of this heater, fuel type configuration and altitude.
Owner's Manual • Oval-U 100