Indoor Capacity Range; Standard Supplied Accessories; Optional Accessories; Technical And Electrical Specifications - Panasonic Urban Multi U-8ME4XPQ Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 107
1.1.

Indoor capacity range

The indoor units can be installed in the following range.
Always use appropriate indoor units compatible with R410A.
To learn which models of indoor units are compatible with
R410A, refer to the product catalogs.
Total capacity of indoor units
Outdoor unit
U-8ME4XPQ
U-10ME4XPQ
U-12ME4XPQ
U-14ME4XPQ
U-16ME4XPQ
NOTE
If the total capacity of the connected indoor units
exceeds the capacity of the outdoor unit, cooling and
heating performance may drop when running the
indoor units.
Refer to the section on performance characteristics in
the Engineering Data Book for details.
1.2.

Standard supplied accessories

See location 1 in figure 18 for reference to where following
accessories are supplied with the unit.
Installation manual
Operation manual
Additional refrigerant charge label
Installation information sticker
Fluorinated greenhouse gases information sticker
See location 2 in figure 18 for reference to where following
accessories are supplied with the unit.
Liquid accessory pipe (1)
Liquid accessory pipe (2)
Suction gas accessory pipe (1)
Suction gas accessory pipe (2)
High pressure/low pressure
accessory pipe (1)
High pressure/low pressure
accessory pipe (2)
Accessory joint (angle of 90°) (1)
Accessory joint (angle of 90°) (2)
Accessory joint
Installation manual
2
Total capacity of indoor units
100~260
125~325
150~390
175~455
200~520
1x
1x
1x
1x
1x
U-XPQ
8
10
12
14
16
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
Ø22.2
1x
Ø22.2
1x
1x
1x
Ø28.6
1x
Ø19.1
1x
Ø22.2
1x
1x
1x
Ø28.6
1x
Ø15.9
1x
1x
Ø19.1
1x
1x
Ø19.1
1x
Ø15.9
1x
1x
Ø19.1
1x
1x
Ø22.2
1x
1x
1x
1x
1x
Ø25.4
1x
1x
1x
1x
1x
Ø19.1
1x
1.3.

Optional accessories

To install the above outdoor unit, the following optional parts are also
required.
Refrigerant branching kit (for R410A only: Always use an appropriate
kit dedicated for your system.)
Refnet header
3 pipes
2 pipes
CZ-P29HK32Q
CZ-P29HK12Q
CZ-P64HK32Q
CZ-P64HK12Q
CZ-P75HK32Q
CZ-P75HK12Q
To select an optimum refrigerant branching kit, refer to "6. Refrigerant
piping" on page 4.
1.4.
Technical and Electrical specifications
Refer to the Engineering Data Book for the complete list of
specifications.
2.
M
AIN COMPONENTS
For main components and function of the main components, refer to
the Engineering Data Book.
Refnet joint
3 pipes
2 pipes
CZ-P20BK32Q
CZ-P20BK12Q
CZ-P29BK32QA
CZ-P29BK12Q
CZ-P64BK32Q
CZ-P64BK12Q
CZ-P75BK32Q
CZ-P75BK12Q
U-8~16ME4XPQ
Urban Multi air conditioner