4
NOTE: The specified cavities in the TIPM may be populated. If so, the existing wires must be removed using a
terminal removal kit, or equivalent to install the fog lamp kit wires.
NOTE: The location of the jumper harness wires (RH
and LH fog lamp 12V power feeds) are not placement
sensitive between TIPM connector C11 cavities 5, 6.
19. Insert the fog lamp jumper harness wire terminals into
TIPM connector C11 cavities 5 and 6.
20. Seat the TPA on the face of the TIPM connector C11.
21. Connect TIPM harness connector C11 (3).
NOTE: Make sure the jumper harness is available for
ward of the TIPM.
22. Position the TIPM (1) and install on the three retaining
clips (2). Lift on the TIPM (1) to make sure the retain
ing clips (2) are secure.
Jan 17, 2011
www.mopar.com
K6861209