Índice
Información general........................................................................................... 4
Introducción .................................................................................................................... 4
FWD
Entrega ............................................................................................................................ 4
Power supply
Capacities
Inventario de accesorios ................................................................................................ 4
Cooling capacity on water (1)
Heating capacity on water (2)
Garantía .......................................................................................................................... 4
Fan motor
Refrigerante .................................................................................................................... 4
Start-up amps
Air flow
Almacenamiento ............................................................................................................ 5
minimum
Formación ....................................................................................................................... 5
Main coil
Water entering/leaving connections
Electric heater (accessory for blower only)
Electric power supply
Heating capacity
Hot water coil (accessory for blower only)
Quantity
G4 filter (filter box accessory)
Not available for FWD30 and FWD45
Instalación ........................................................................................................ 17
Sound pressure level (5)
Sound power level (5)
Entrega de las unidades .............................................................................................. 17
Unit dimensions
Width x Depth
Height
Instalación de la unidad ............................................................................................... 18
Recommended fuse size
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
FWD:
Accessories - Hot water coil:
*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars
Conexiones eléctricas .................................................................................................. 24
2
4
© 2020 Trane
Technical Data
08
(V/Ph/Hz)
5,2
6,3
(type)
(kW)
0,23
(A)
1,1
(A)
3,2
(m
/h)
490
3
(m
/h)
820
3
(m
/h)
980
3
(type)
(Dia)
3/4"
(V/Ph/Hz)
230/1/50
(kW)
2/4
6,3
2
(mm)
386x221x8
-
(mm)
-
(type)
(l/h - mm)
(dB(A))
36/40/43
(dB(A))
46/50/53
(mm)
890 x 600
(mm)
250
(mm)
933 x 644
260
32
(A)
8/16
(A)
16 (2kW),25 (4kW)
12
20
230/1/50
8,3
15
11,9
18,9
0,46
0,65
2,2
3,1
5,5
9,3
980
1400
1650
2300
1970
2600
ISO R7 rotating female
3/4"
1 1/2"
230/1/50 or 400/3/50
400/3/50
8
10
12
17,4
2
2
586x321x8
2
2
Centrifugal
24 - 500
38/41/44
46/50/53
48/51/54
56/60/63
1090 x 710
1290 x 820
300
350
310
360
46
61
8/16
8/16
3*20
30
45
18,8
30,1
20,9
38,2
1,04
1,51
4,7
5,5
14,1
16,5
1800
2700
3000
4500
3600
5400
1 1/2"
1 1/2"
400/3/50
400/3/50
12
12
22,4
34,5
2
2
586*421*8
586*621*8
2
2
586*414*48
586*614*48
47/52/57
47/52/58
57/62/67
57/62/68
1290 x 970
1290 x 1090
450
650
1333*1133
460
660
76
118
8/25
8/25
3*25
3*25
UNT-PRC002-GB
RT-SVX060C-ES