Storage-to-Panel
Connector
(continued)
7.
Remove bracket assembly
and drill 5/16" diameter holes at
all marked positions.
8.
Flip the bracket assembly
back to its upright position and
reinstall onto panel.
NOTE:
Make sure the "UP"
identification mark on the bracket
assembly is pointing "up".
9.
Make sure the safety clip is
fully engaged into the panel slot
(9a). To verify the safety clip is
engaged properly, lift up firmly
on studs (9b).
A properly installed clip will not
allow the bracket assembly to
move. If the bracket assembly
moves up during the lifting
action, check safety clip
engagement again.
8
BRACKET
ASSEMBLY
7
CAUTION
When properly installed,
CRUSH HAZARD
when lifted up firmly. Do not exceed 8 ft-lb of nut torque.
Be sure to engage safety
Storage-to-panel connectors can only be used with select
Steelcase storage products identified by the assembly
clip. Failure to properly
directions. Read the entire Assembly Direction 939500592
secure bracket could
before beginning installation. Obtain Assemby Directions
result in personal injury.
from your local Steelcase dealer or by calling 1-888-783-3522.
9b
9a
9b
the bracket will not disengage
SAFETY CLIP
Page 9 of 39
76456 Rev C