Descargar Imprimir esta página

Remedy Of Faults - Oase Aquarius Eco Expert 22000 Instrucciones De Uso

Ocultar thumbs Ver también para Aquarius Eco Expert 22000:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 34
Commissioning/start-up
N O T E
Sensitive electrical components. Incorrect connection will destroy the unit.
• Do not connect the unit to a dimmable power supply.
When started up, the pump automatically performs a pre-programmed self-test of approx. two minutes length (Envi-
ronmental Function Control (EFC)). The pump detects if it is running dry / blocked or submerged. The pump
switches off automatically after approx. 90 seconds if it runs dry (is blocked). In the event of a malfunction, disconnect
the power supply and flood the pump or remove the obstacle. Following this, the unit can be restarted.
Switching on: Connect the unit to the mains. The unit switches on immediately.
Switching off: Disconnect the unit from the mains.
Dynamic Function
How to proceed:
 G
• Slide the switch.
– ON: The function is activated.
– OFF: The function is deactivated.
N O T E
When the Dynamic Function is activated, the function of the EFC (Environmental Function Control) is limited.
• The unit is not protected from running dry.

Remedy of faults

Malfunction
Pump does not start
Pump does not deliver
Insufficient delivered quantity
Pump switches off after a short running period
Cause
No mains voltage
Filter housing clogged
Excessively soiled water
Impeller unit blocked
Filter housing clogged
Excessive loss in the supply lines
Excessively soiled water
Water temperature too high
Impeller unit blocked
Pump has run dry.
Remedy
− Check the mains voltage
− Check supply lines
− Clean
− Clean pump. The pump automatically
switches on again once the motor has
cooled down.
− Disconnect the power supply and remove
obstacle. Then switch the pump on again.
− Clean
− Select larger hose diameter
− Reduce hose length to reduce frictional
loss
− Avoid unnecessary connection elements
− Clean pump. The pump automatically
switches on again once the motor has
cooled down.
− Note maximum water temperature of
+35°C. The pump automatically switches
on again once the motor has cooled down.
− Disconnect the power supply and remove
obstacle. Then switch the pump on again.
− Flood pump. Fully submerge the unit when
operated in the pond.
- EN -
17

Publicidad

loading

Este manual también es adecuado para:

Aquarius eco expert 28000