- EN -
Installation and connection
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
• Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
• Isolate the device (disconnect from the power supply) before carrying out any work on it.
W A R N I N G
Death or serious injuries from hazardous electrical voltage due to operation of this unit in a swimming pond.
• Never operate this unit in a swimming pond.
Operating the unit in the pond
C
• Never operate the pump in a swimming pond.
• Only operate the pump when it is below the water surface level.
• Only operate the pump with the filter basket fitted.
• Ensure that the pump is in a secure and stable position.
N O T E
If the pump is used for conveying excessively soiled water, the impeller unit will be subject to increased wear and will
require earlier replacement.
Remedy:
• Thoroughly clean the pond or pool before installing the pump.
• Install the pump approx. 200 mm above the floor of the pond to avoid excessively soiled water from being drawn into
the pump.
How to proceed:
E
1. Screw the stepped hose adapter including union nut and sealing ring to the outlet.
2. Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the hose clip.
Install the unit at a dry place
D
• Swimming pond or pool that may be accessed by people.
– Install the unit at least 2 m away from the water.
• Do not expose the unit to direct sunlight.
• Ensure that the pump is in a secure and stable position.
How to proceed:
F
1. Remove the screws for fastening the filter basket and remove the filter basket.
2. Screw the hose connector with union nut and seal onto the inlet.
3. Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the hose clip.
4. Screw the hose connector with union nut and seal onto the outlet.
5. Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the hose clip.
6. Fasten the pump to a suitable base using screws (not included in the scope of delivery).
N O T E
Recommendations for hoses and pipes:
• Use 50 mm (2 ") hose connectors and hoses for a length of up to 5 m.
• Use DN 75 or DN 100 pipes for a length greater than 5 m.
16