CHAFFOTEAUX ChaffoLINK Instrucciones De Instalacion Y Uso página 57

Ocultar thumbs Ver también para ChaffoLINK:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 71
Type 1
Activation of RD and RC in a basic
heating system.
(Fig.1)
System
where
product is connected exclusively to a
single ON/OFF temperature regulation
accessory and you need to go there
to activate the Chaff olink Remote
Diagnostics
and
services.
Actions required (Fig. 2):
- Remove the ON/OFF accessory
and disconnect the bipolar cable
from the TA input of the boiler
- Install the Chaff olink Gateway,
connecting it to the boiler through
the serial port and the TA input.
- Install the Chaff oteaux Room Sensor,
connecting it to the Gateway via the
BridgeNet BUS connection
Type 2
Activation of RD and RC on a system
with 2 or more plumbing zones
controlled by ON/OFF devices. (Fig. 3)
System in which there are zone
management
devices
by ON/OFF temperature regulation
accessories.
Actions required (Fig. 4):
- Install an Chaff oteaux Multifunction
Kit in an appropriate position
- Remove all temperature regulation
accessories in the system and
replace them with Chaff oteaux
Room Sensors, connecting them
to the multifunction kit via the
BridgeNet BUS connection.
the
Chaff oteaux
Remote
Control
controlled
THERMOSTAT
TA
GATEWAY
Room Sensor
SERIAL
BUS BridgeNet
TA
Fig. 3
TA1
TA2
Fig. 1
Fig. 2.
57

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

33188893318891

Tabla de contenido