Indicators
Below we describe the characteristics of the LEDs used in the
phases of both configuration and normal operation.
LED
At the top right of the speech units there are three LEDs with
the following meanings starting from top to bottom:
LED
Meaning
green LED:
- on -> communication indicator on,
- blinking -> call in progress indicator (0.5 sec on,
0.5 sec off, cycle 1 s).
Green indicator LED,
on -> during lock operation.
Red LED: flashing in case of lost communication
- on -> signalling Bus busy
- blinking -> signalling lost communication
Red LED
:
Situation
Attempt to call with BUS
busy
Call to indoor unit with
chime off
Call to busy indoor unit
The called indoor unit does
not exist
Secondary ID assignment
with parent > 50
In the other states the LEDs are off.
EN
On
Period
Duration
(s)
(s)
(s)
0.1
0.2
2
0.1
0.2
5
0.2
0.4
5
0.1
0.2
1
0.1
0.2
1
White LEDs:
Situation
The chosen configuration
has a value that is not
among the standard ones
(it has been changed with
SaveProg)
Resetting to the factory
configuration value is in
progress
Indoor unit automatic ID
assignment input, waiting
to choose from which
button to start
The speech unit is
searching to check
whether there is another
one with the same ID
Waiting to check whether
there is another speech
unit with the same ID
Pushbutton remapping
Waiting for ordering
modules Art. 41010
The situation of remaining in bootloader lasts 10 s from entry.
It exits automatically if the update is not started. The situation
is indicated by a single white LED coming on, the one at bot-
tom right, at the same time as the green LED signalling active
communication/ongoing call.
On
Period
(s)
(s)
0.1
0.5
0.1
0.2
0.5
0.25
0.25
Note: They are each
offset by 0.25 s and
thus appear to rotate
clockwise
The
LED
paired
with the button to be
N.O.
remapped remains lit
steady
0.5
1
1
1
1
29