Descargar Imprimir esta página

TFA MusiCONTROL DE10016 Instrucciones Para El Manejo página 5

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

TFA No. 30.5009 Anleitung 13.07.2006 11:11 Uhr Seite 5
MusiCONTROL
Digital thermo-hygrometer
Tips:
• Always store instrument in case or cover
• Do not hang instrument on the wall (fluctuating climate,
dust, risk of mechanical damage)
• Best stored in moderately heated rooms (e.g. bedroom)
• Avoid severe temperature fluctuations
• In summer never leave instruments in car
• Avoid direct sunlight (even if stored in case)
• Do not place near radiators or underfloor heating
• If the room air is too dry, particularly in wintertime, then
electrical air humidifiers are recommended.
Operation:
Startup:
Remove the battery safety strip. Pull off the protection foil
on the display. The unit is now ready to use.
Display:
The left row shows the indoor relative humidity and the
right row the room temperature. The temperature unit can
be changed from °C to °F by the °C/°F-button at the backside.
If the humidity is between 45 % and 65 %, a clef appears on
the display as an indicator of ideal storage conditions. If the
humidity falls to below 45 % or rises above 65 % the treble
clef starts to flash. If levels are below 40 % or above 75 %,
the note key disappears and the red light flashes. The warn-
ing signal can be switched on and off with the slide switch
on the back.
8
MusiCONTROL
Digital thermo-hygrometer
MAX/MIN temperatures:
• Press the MAX/MIN button and the highest temperature
and humidity is displayed since the last reset.
• Press the MAX/MIN button again, the display shows the
lowest temperature and humidity since the last reset.
• To go back to the present values, press the MAX/MIN
button once more.
• Press the RESET button to reset the MAX/MIN values to the
present temperature.
Placing or hanging up the unit:
A circular opening is provided on the rear-side of the unit for
hanging on the wall. To place the unit in the standing posi-
tion use the foot supplied with the unit.
As the humidity in rooms can vary greatly depending on the
part of the room, place the monitoring device as close as
possible to the instrument.
Battery replacement:
Remove the stand if necessary. Lightly push the silver battery
lid on the front down and open the battery compartment.
Replace the batteries (2 x 1.5 V AA). Do not use rechargeable
batteries.
Attention:
Please do not dispose of old electronic devices and used bat-
teries in household waste.
To protect the environment, take them to your retail store or
to nearest civic amenity site to be disposed of according to
national or local regulations.
9

Publicidad

loading

Este manual también es adecuado para:

30.5009