OBJ_DOKU-20994-002.fm Page 16 Monday, June 27, 2011 12:55 PM
16 | English
Do not use the laser viewing glasses as sun glasses or in
traffic. The laser viewing glasses do not afford complete
UV protection and reduce colour perception.
Have the measuring tool repaired only through quali-
fied specialists using original spare parts. This ensures
that the safety of the measuring tool is maintained.
Do not allow children to use the laser measuring tool
without supervision. They could unintentionally blind
other persons or themselves.
Do not operate the measuring tool in explosive environ-
ments, such as in the presence of flammable liquids,
gases or dusts. Sparks can be created in the measuring
tool which may ignite the dust or fumes.
Do not open the battery pack. Danger of short-circuiting.
Protect the battery pack against heat, e.g.,
against continuous intense sunlight, fire, water,
and moisture. Danger of explosion.
Keep the battery pack not being used away from paper
clips, coins, keys, nails, screws or other small metal ob-
jects that can make a connection from one terminal to
another. Shorting the battery terminals together may
cause burns or a fire.
Under abusive conditions, liquid may be ejected from
the battery pack; avoid contact. If contact accidentally
occurs, flush with water. If liquid contacts eyes, addi-
tionally seek medical help. Liquid ejected from the bat-
tery may cause irritations or burns.
Charge the battery pack only with the battery charger
specified in these operating instructions. A charger that
is suitable for one type of battery pack may create a risk of
fire when used with another battery pack.
Use only original Bosch battery packs with the voltage
listed on the nameplate of your measuring tool. When
using other battery packs, e.g. imitations, reconditioned
battery packs or other brands, there is danger of injury as
well as property damage through exploding battery packs.
Keep the laser target plate 37 away from
cardiac pacemakers. The magnets on the
laser target plate generate a field that can
impair the function of cardiac pacemakers.
Keep the laser target plate 37 away from magnetic data
medium and magnetically-sensitive equipment. The ef-
fect of the magnets on the laser target plate can lead to ir-
reversible data loss.
Battery Charger
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions
may result in electric shock, fire and/or serious in-
jury.
Keep the battery charger away from rain or
moisture. Penetration of water in the battery
charger increases the risk of an electric shock.
Do not charge other batteries with the battery charger.
The battery charger is only suitable for charging the Bosch
1 619 929 J22 | (27.6.11)
battery/battery pack inserted in the rotational laser level.
Danger of fire and explosion when charging other batter-
ies/battery packs.
Keep the battery charger clean. Contamination can lead
to danger of an electric shock.
Before each use, check the battery charger, cable and
plug. If damage is detected, do not use the battery
charger. Never open the battery charger yourself.
Have repairs performed only by a qualified technician
and only using original spare parts. Damaged battery
chargers, cables and plugs increase the risk of an electric
shock.
Do not operate the battery charger on easily inflamma-
ble surfaces (e. g., paper, textiles, etc.) or surround-
ings. The heating of the battery charger during the charg-
ing process can pose a fire hazard.
Under abusive conditions, liquid may be ejected from
the battery pack; avoid contact. If contact accidentally
occurs, flush with water. If liquid contacts eyes, addi-
tionally seek medical help. Liquid ejected from the bat-
tery may cause irritations or burns.
Supervise children. This will ensure that children do not
play with the charger.
Children or persons that owing to their physical, senso-
ry or mental limitations or to their lack of experience or
knowledge, are not capable of securely operating the
charger, may only use this charger under supervision
or after having been instructed by a responsible per-
son. Otherwise, there is danger of operating errors and in-
juries.
Products sold in GB only: Your product is fitted with a
BS 1363/A approved electric plug with internal fuse
(ASTA approved to BS 1362).
If the plug is not suitable for your socket outlets, it should
be cut off and an appropriate plug fitted in its place by an
authorised customer service agent. The replacement plug
should have the same fuse rating as the original plug.
The severed plug must be disposed of to avoid a possible
shock hazard and should never be inserted into a mains
socket elsewhere.
Laser Receiver
Read and observe all instructions. SAVE
THESE INSTRUCTIONS FOR FUTURE REF-
ERENCE.
Keep the measuring tool away from car-
diac pacemakers. The magnet plate 22
generates a field that can impair the func-
tion of cardiac pacemakers.
Keep the measuring tool away from magnetic data me-
dium and magnetically-sensitive equipment. The effect
of the magnet plate 22 can lead to irreversible data loss.
Have the measuring tool repaired only through quali-
fied specialists using original spare parts. This ensures
that the safety of the measuring tool is maintained.
Bosch Power Tools