2. Make sure that the front grid (2) is open
and that the panel heater is not covered.
The front grill must always be kept free
during the heating operation. The panel
heater must not be covered when it is in
use.
3. Use the power switch (3) and the rotary
thermostat switch (7) for the heating
function, as described below.
4. When the panel heater is not in use, or
when it is moved, cleaned or stored, press
the power switch (3) to the OFF position
(4) and disconnect the power plug (14)
from the power socket. During transport,
always use the transport grip (13) at the
back of the panel heater.
Power switch and rotary thermostat switch
1. Press the power switch to the ON position
(5). The power lamp lights up.
2. Turn the rotary thermostat switch (7) in a
clockwise direction to the highest position.
The temperature control lamp (8) lights up.
3. When the desired temperature is reached,
turn the rotary thermostat switch (7) in an
anti-clockwise direction until you hear a
clicking noise. Now the panel heater has
switched off the heating function.
4. Now turn the rotary thermostat switch (7)
back slightly in a clockwise direction. The
panel heater now switches the heating
function on and off automatically so as to
maintain the desired room temperature.
The temperature control lamps (8) go on
and off accordingly.
5. The further you turn the rotary thermostat
switch (7) in a clockwise direction, the
higher the heating temperature will be.
6. In order to make it easier to set a
comfortable room-temperature, choose a
setting within the marked comfortable
temperature zone (10).
7. When the thermostat is set to the frost
protection function (9) and the power
switch (3) is ON, the panel heater begins
to heat as soon as the room temperature
drops below about + 5 °C. The panel
heater will continue the heating operation
until the room temperature has risen to
above about + 5 °C.
ENGLISH
8. When the rotary thermostat switch (7) is
at the highest position (11), you cannot
turn it in a clockwise direction, but only in
an anti-clockwise direction.
ECO-Function
1. The ECO-Function switches itself on as
soon as the set room temperature has
more or less been reached. The green
ECO control lamp (6) lights up.
2. The panel heater is now heating with a
third less energy:
1000 Watt runs with 650 Watt
1500 Watt runs with 1000 Watt
Overheating protection
1. The panel heater is equipped with
overheating protection which
automatically switches off the panel
heater if it overheats.
2. If this happens, switch the power switch
(3) to the OFF position (4) and disconnect
the power plug (14) from the power socket.
3. Allow the panel heater to cool for at least
20 minutes.
4. Now remove any objects which may have
got into, in front of or onto the panel
heater and caused the faulty functioning
or overheating.
5. Resume using the panel heater as
described in the „user's manual".
CLEANING AND STORAGE
We recommend that you clean the panel
heater regularly. To avoid impairing the func-
tioning of the panel heater, please follow the
instructions for cleaning and storage.
Cleaning
1. Before you start cleaning the panel heater,
press the power switch (3) to the OFF
position (4) and disconnect the power
plug (14) from the power socket.
2. Clean the frond grid (2) with the brush
attachment of your vacuum cleaner.
3. Wipe the outer surfaces of the panel
heater with a soft, damp cloth.
4. Resume using the panel heater as
described in the „user's manual".
7