Sensor with potentiometer (WL14-2P430S02):
The sensitivity is adjusted with the potentiometer (type: 360°). Clockwise rotation:
operating reserve increased; counterclockwise rotation: operating reserve reduced.
We recommend setting the potentiometer to "Maximum". A lower operating reserve
may be necessary for depolarizing surfaces.
The sensor is adjusted and ready for operation. Refer to Graphics C and G to check
the function. If the switching output fails to behave in accordance with Graphic C,
check application conditions. See section Fault diagnosis.
Sensor with teach-in button (WL14-2Xxx1):
As a rule, it is not necessary to teach-in the sensor.
A lower operating reserve may be necessary for depolarizing surfaces (e.g., tape).
The sensitivity is adjusted according to Table J by pressing the teach-in button. Do
not operate the teach-in button using sharp objects.
The sensor is adjusted and ready for operation. Refer to Graphics C and G to check
the function. If the switching output fails to behave in accordance with Graphic C,
check application conditions. See section Fault diagnosis.
Image: C
Image: G
3
COMMISSIONING
3