- ASSEMBLY
Secure the safety strips in the conveyance or deflection area, depending on gate/
door high (max. 2,5 m) and secure one RED per each nearby.
Connect each safety strip contact to the J3 terminal of its RED.
Both NO or NC safety strip contact may be used, hence select trough the JP2
jumper the type of contact used.
It's strictly necessary to connect a 8.2kΩ 1/4w resistor in series (if the
safety strip contact is NC) or in parallel (if the safety strip contact is NO).
If 8,2 KΩ 1/4 W resistor is not connected, system stops and starts alarm.
MECHANICAL SAFETY STRIP connection
R = 8,2 KΩ
ELECTRICAL SAFETY STRIP connection
16
R = 8,2 KΩ