RED TRANSMITTERS MEMORIZATION ON MASTER Wi-Fi
Use the following procedure for memorization:
- Push the button PROG RX on the MASTER Wi-Fi => dual-color LED EDGE
PHOT 1 flashes red for 1 minute (the time needed for memorization).
- Push the button PROG TX (S2) on the safety device with micro-switch 1
in the ON position => on the MASTER Wi-Fi the dual-color LED EDGE PHOT 1
flashing red turns green and a sound from the buzzer indicates that the safety
device has been memorized correctly, immediately the dual-color LED EDGE
PHOT 2 begins flashing red.
- If there are no other safety devices to be memorized after one minute
the dual-color LED EDGE PHOT 2 will turn off or, push the button PROG. RX 4
times to end the memorization procedure => all of the dual-color LED EDGE
PHOT should be off.
MEMORIZATION OF OTHER SAFETY DEVICES
- After having memorized the first safety device, the dual-color LED EDGE
PHOT 2 automatically begins flashing red for 1 minute (the time needed for
memorization).
- Push the button PROG. TX (S2) on the safety device with micro-switch 2 in the
ON position => on the MASTER Wi-Fi the dual-color LED EDGE PHOT 2 flashing
red turns green and a sound from the buzzer indicates that the safety device has
been memorized correctly.
- Follow the same procedure for any other safety devices (up to a maximum of 6).
SYSTEM CHECK
After having calibrated the TOUCH strip correctly:
- Push the contact of a TOUCH strip (for example: safety device number 3).
- On the MASTER Wi-Fi check that the corresponding LED EDGE PHOT 3 flashes
green and that the paired LED DL2 momentarily turns off and then turns on.
ATTENTION: after receiving the first signal, other signals are ignored for 2
seconds. If there is a signal in these 2 seconds it will be from the LED EDGE
PHOT 3 which turns green.
- Repeat the LED activation check on the MASTER Wi-Fi pushing the other TOUCH
strips installed.
- Perform a final check of all of the strips installed, activating the movement of the
automation and ensuring that upon impact with the strip the automation stops/
reverses movement.
ALARM SIGNAL CHECK
Check that by taking the battery out of the transmitter with micro-switch, for
example DIP3 in the ON position, the dual-color LED EDGE PHOT 3 on the MASTER
Wi-Fi alternates red and green while LED DL2 turns off, and that the buzzer emits
an alternating sound for 1 minute.
Repeat the check for any other strips installed.
Note: if the battery is removed and the buzzer on the MASTER Wi-Fi does not
sound, micro-switch 3 on the MASTER Wi-Fi is in the OFF position (go-ahead not
enabled). Turn it to ON.
WARNING (replace the batteries)
The WARNING tells the user of the immediate need to replace the batteries.
When battery power reaches 3V the strip signal the MASTER Wi-Fi via radio of
the low battery status and activate the BUZZER of the MASTER Wi-Fi with a sound
every 3 seconds for 1 minute.
The warning is renewed for 1 minute if a command is given to the door.
The dual-color LED on the MASTER Wi-Fi corresponding to the photocell or the
strip with the low batteries emits a constant red light.
The SPARK Wi-Fi blinker (if available) indicates the warning by emitting 2
consecutive flashes followed by a pause for 3 seconds for the duration of
the opening or closing of the door.
The system is still operational during these signals, but it is advantageous to
replace the batteries as soon as possible in order to avoid a full stop of the door
operation which happens when the batteries reach 2,7V.
ALARM (batteries completely exhausted or not working)
The alarm activates when the batteries are completely exhausted (2,7V) or when
they stop working.
On the MASTER Wi-Fi the LEDs DL2 and DL3 turn off MASTER Wi-Fi blocks the
automation.
On the MASTER Wi-Fi the dual-color LED corresponding to the strip with the low
or non-functioning batteries flashes alternately red and green. The BUZZER emits
an alternating sound for 1 minute, while the SPARK Wi-Fi blinker (if available)
signals the alarm status by emitting emitting 2 consecutive flashes
followed by a pause for 3 seconds, notifying the user that the batteries must
be replaced or repaired.
The alarm is renewed for 1 minute if a command is given to the door.
TOTAL REMOVAL PROCEDURE FOR MEMORIZED SAFETY DEVICES
To perform a total removal of the safety devices recorded in the MASTER Wi-Fi
memory just push and hold the button PROG. RX for 10 seconds. After 10
seconds all of the dual-color LEDs (from EDGE PHOT 1 to EDGE PHOT 6) will flash
alternately 6 times, indicating successful removal.
Afterwards the dual-color LED EDGE PHOT and LEDs DL2 and DL3 will turn off.
ATTENTION: WITH LED DL2 AND DL3 OFF AUTOMATION DOES NOT WORK.
REMOVAL PROCEDURE FOR A SINGLE SAFETY DEVICE
In order to remove a single memorized safety device on the MASTER Wi-Fi, use
the following procedure:
- Push the button PROG. RX one or more times to select the dual-color LED EDGE
PHOT which begins flashing green, corresponding to the safety device to be
eliminated.
- After selecting the safety device, push and hold the button PROG. RX for 10
seconds.
- After 10 seconds the dual-color LED EDGE PHOT flashes alternately red and
green 6 times, indicating successful removal.
ATTENTION: Place the micro-switch corresponding to the eliminated safety
device in the OFF position, then scan the dual-color LED pushing the button
PROG. RX 6 times.
REPLACING THE BATTERIES
The lifespan of the 1.5 V AA batteries used in the safety devices is about 3 years.
In case it is required to replace the batteries, it will not be necessary to re-program
the safety strips, nor any other RIB Wi-Fi accesories.
- Identify the safety device with the exhausted batteries by checking the diagnostic
of the LED EDGE PHOT on the MASTER Wi-Fi.
- Using the number on the side of the dual-color LED EDGE PHOT which is flashing
red and green or that emits a constant red light identify the number of the safety
device with the exhausted batteries.
- Find the device with the adhesive strip bearing the identification number
corresponding to the number of the dual-color LED which is in alarm status on
the MASTER Wi-Fi.
- Replace the batteries, checking that the polarity is correct.
- Push button PROG TX on the TOUCH to restart the MASTER Wi-Fi.
- The buzzer on the strip of the MASTER Wi-Fi will turn off and the LEDs DL2- DL3
(if in alarm status) will come on. The dual-color LED corresponding to the safety
device with the replaced batteries will turn off.
The automation is now ready for safe operation.
ATTENTION: Please remember that batteries must be disposed of properly
according to current standards. In case of disposal of the safety devices please
remember to remove the AA batteries and dispose of them properly.