LECOM-fault number, display in parameter setting program Global Drive Control (GDC)
L
Error
Cause
Controller
Controller too hot inside
overtemperature
PTC monitoring
Motor too hot because of excessive
currents or frequent and too long
(is displayed if
accelerations
C0119 = 2 or 5)
C0119 = 2 or 5)
PTC not connected
DC-bus overvoltage
Mains voltage too high
(Warning or TRIP
(
g
configurable under
fi
bl
d
Braking operation
C0310)
Earth leakage on the motor side
Faulty parameter
All parameter sets are defective
transfer when using
the keypad
Wrong PAR1 transfer
PAR1 is defective.
when using the
keypad.
Wrong PAR2 transfer
PAR2 is defective.
when using the
keypad.
Wrong PAR3 transfer
PAR3 is defective
when using the
keypad.
Wrong PAR4 transfer
PAR4 is defective
when using the
keypad.
Internal fault
EEPROM is defective
Time fault during
Data flow from keypad or PC
parameter set transfer
interrupted, e. g. keypad was
disconnected during transfer
Faulty auto-TRIP reset
More than 8 fault messages in
10 minutes
Wire breakage analog
Current at analog input < 4 mA at
input 1
setpoint range 4 ... 20 mA
Wire breakage analog
input 2
Remedy
Reduce controller load
Improve cooling
Check fan in the controller
Check drive selection
Connect PTC or switch off monitoring
Check voltage supply
Prolong deceleration times.
Operation with external brake resistor:
– Check dimensioning, connection and
cable of the brake resistor.
– Increase the deceleration times
Check motor cable and motor for earth fault
(disconnect motor from inverter)
It is absolutely necessary to repeat the data
transfer or load the Lenze setting before
enabling the controller.
enabling the controller.
Contact Lenze
It is absolutely necessary to repeat the data
transfer or load the Lenze setting before
enabling the controller.
Depends on the error message
Close circuit at analog input
11