Installation • Instalación
Installation • Instalação
wrong • no correcto
incorrect • incorrecto
6
correct • correcto
correct • correcto
english
1. Feed pipe and fitting at least 1"!
(internal dia. > 22 mm)
2. No filters in feed line!
3. Slope in feed line > 1 %!
4. Only use ball valves!
5. Pressure: min. 0.8 bar or 1.2 bar!
(check type plate for correct
pressure)
6. Short pressure hose!
7. For each metre of rising slope in
the outlet line, the required
minimum pressure will increase
by 0.1 bar.
The rise of the outlet line must not
exceed 5 metres!
8. Collecting line min. 1" with 1%
slope!
9. Always install a venting line!
10. The upper ¾" connection should
only be used as a condensate
inlet in exceptional cases since
this could lead to inflow problems.
Note: Pressure differences!
Each condensate source must be
drained separately!
In the case of condensate inflow from
the top, the feed line should preferably
be short (internal dia > 18 mm).
In the case of inflow problems, install
venting line.
Note: Venting line
The BEKOMAT 16 should always be
installed with a venting line when fee-
ding into the bottom part..