MENU
The test of photocells to PHOT O input is enabled or disabled.
TST1
On: Test is enabled. If the test is negative, no operation is performed.
Off: Test is disabled.
The test of photocells to PHOT C input is enabled or disabled.
TST2
On: Test is enabled. If the test is negative, no operation is performed.
Off: Test is disabled.
The operating mode of the PHOT C input is selected.
On: PHOT C input is activated in both opening and closing phases.
In the opening phase: the contact opening causes the motor stop. When the
photocell is released, the motor restarts in the opening phase.
PHTC
In closing phase: the contact opening causes the motor stop. When the
photocell is released, the motor inverts the movement direction (open).
Off: The PHOT C input is activated in the closing phase only.
In the closing phase: the contact opening causes the motor stop and the
immediate reversion of the operation direction (open).
MENU
By selecting this function, the receiver awaits (Push) for a transmitter code to be assigned to the step-by-step
function.
PP
Press the transmitter key to be assigned to this function.
If the code is valid, it is stored in memory and OK appears.
If the code is not valid, the wording Err is displayed.
By selecting this function, the receiver awaits (Push) for a transmitter code to be assigned to the second radio
channel.
2ch
Press the transmitter key to be assigned to this function.
If the code is valid, it is stored in memory and OK appears.
If the code is not valid, the wording Err is displayed.
By selecting this function, the receiver awaits (Push) for a transmitter code to be erased from memory.
CLr
If the code is valid, it is erase and OK appears.
If the code is not valid or is not in memory, the wording Err is displayed.
RTR
Completely erase the receiver memory. Confirmation of operation is required.
MENU
Displays the number of complete cycles (open+close) carried out by the automation.
NMAN
When the <PG> button is pressed for the first time, it displays the first 4 figures, the second time it shows the
last 4. Example <PG> 0012
RESET of the control unit. ATTENTION!: Returns the control unit to the default values.
Pressing the <PG> button for the first time causes blinking of the letters RES, pressing the <PG> button again
RES
resets the control unit.
Note: The transmitter codes are not erased from the receiver.
With ENC=ON LOGICS:
-
the anti-crashing sensor is activated. Adjust the sensitivity through parameters SEAV and SEAR in compliance with regulations in
force. An accurate adjustment of the motor brake (IBRA parameter) can help to comply with regulations in force.
-
if the parameter TSM>0 (braking activated), the first opening and closing operations are carried out at reduced speed to permit
the self-learning of the gate leaf stroke. If self-learning is not required, the first operation is carried out at normal speed.
Once the stroke is recorded, the control unit will automatically control braking in both opening and closing phases.
Braking space can be increased or decreases through TSM parameter.
This recording phase is carried out also in case of power failure or activation of braking (TSM from 0 to >0)
With ENC=OFF LOGICS:
-
the anti-crashing sensor is deactivated.
-
if the parameter TSM>0 (braking activated), the first operation is carried out at normal speed to permit the self-learning of the
gate leaf stroke.
FUNCTION
>>> <PG> 3456: made 123.456 cycles.
Operating mode with enabled/disabled Encoder
FUNCTION
FUNCTION
Settable values
MEMO
ON-OFF-(Default)
(OFF)
(OFF)
(OFF)
13