to prolong the heat exhaust hose gently.
Note: Do not separate the heat exhaust hose assembly from the unit. Do not tilt the unit when pulling
apart the heat exhaust hose.
Installation of the window sealing board assembly
Half open the window and mount the window sealing board assembly onto the window, either vertically or
horizontally (as shown in Figure 7 and 8).
Installation of the unit
Move the unit with the heat exhaust hose assembly installed before the window and keep the unit at least
50cm away from the walls or other objects. (As shown in Figure 9).
Snap the flat end of the heat exhaust hose short connector into the elliptical hole of the window sealing
board assembly (as shown in Figure 10and 11).
Note: 1. The flat end of the heat exhaust hose short connector must be snapped into place.
2. The heat exhaust hose may not be bent and shall be free from significant (greater than 45°)
flexure, and the heat exhaust hose shall be ventilated properly
Important notes:
The exhaust hose is 280mm-1500mm long and this length is determined based on the specification
of the air-conditioner (s). Do not use prolonged hose or replace with other different hoses as this
may affect the functions of the air-conditioner. The exhaust must be smooth and the air-conditioner
may overheat if the exhaust is obstructed.
Fig. 7
Fig. 10
Fig. 8
Fig. 9
.
Fig. 11