Descargar Imprimir esta página

EGAmaster 79760 Manual De Instrucciones página 45

Publicidad

Idiomas disponibles

Idiomas disponibles

Hydraulic system requirements
The following is required for an optimum performance of the hydraulic drive unit:
-
Provide a volume flow of 15 to 50 l/min at an operating pressure of 90 to 140 bar.
-
The system should not have more than 17 bar back pressure. The system conditions
for measurement are at maximum fluid viscosity of 82 centistokes (minimum operating
temperature).
-
The hydraulic system should have sufficient heat rejection capacity to limit the maximum
oil temperature to 60° C at the maximum expected ambient temperature.
It is recommended:
-
That filter elements are sized for a volume flow of at least 114 lpm for cold temperature
startup and for maximum dirt holding capacity.
-
The hydraulic system should have a minimum of 10-25 micron full-flow filtration.
Connecting the hydraulic supply to the hydraulic drive unit
Your hydraulic drive unit is an open center tool.
WARNING – Never use the hydraulic drive unit without a pressure reducing valve in line! The
recommended setting for the pressure reducing valve is 145-155 bar.
IDENTIFICATION
INSTALLATION
45

Publicidad

loading