Wiring Instructions; Maintenance Instructions - S&P SWF-100 Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Note: Be certain to make an airtight seal around all interior wall penetrations before
attaching duct work.
Electrical Connection
All SWF series fans operate from a standard 120V 60Hz A.C electrical supply. All wiring must be
carried out in accordance with National Electrical Code, and all applicable state and local buildings
codes.

WIRING INSTRUCTIONS

WARNING! Make sure that power supply is disconnected and locked to prevent accidental
activation.
1. Remove the screws securing the terminal box cover plate located on the fan motor mounting
bracket. All fan motor and capacitor connections are pre-wired to the electrical terminal strip. A
3/8" romex type cable restraint connector will be needed to secure the wiring through the knockout
provided on the side of the terminal box.
2. Bring incoming electrical service through the romex connector and the fan electrical service
opening. Using a small regular screwdriver, tighten the neutral (white) wire of the incoming 115V
power supply under the open terminal strip port opposing the motor Blue wire. Tighten the line
(black) wire of the incoming supply under the open terminal opposing the motor Black wire. Now,
secure the source ground to the open terminal strip opposing the Green/Yellow Wire.
3. Secure the romex connector. Secure the incoming supply with the romex connector. Replace
the fan terminal box cover.
4. Apply a generous bead of silicone caulk around the electrical provision hole in the backplate of
the fan to provide for a secure seal.

MAINTENANCE INSTRUCTIONS

1. Since fan bearings are sealed and provided with an internal lubricating material, no additional
lubrication is necessary.
2. It is recommended that the cover is screen is checked on a regular basis to check for any ob-
structions and the cover is removed and the motor and wheel are inspected and cleaned as nec-
essary.
No other maintenance is necessary.