Battery Charging; Charger Symbols - Senco Fusion F-35XP Instrucciones De Empleo

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 67

Battery Charging

EN
1.
Place battery pack in charger.
2.
Align raised ribs on battery pack with groove in charger.
3.
Press down on battery pack to be sure contacts on battery pack engage properly with contacts in charger. When properly connect-
ed, the red light will turn on. Red flashing light indicates fast charging mode.
4.
Red and green light flashing indicates defective battery pack. Return battery pack to your nearest SENCO Authorized Service Center
for inspection or replacement.
5.
Solid red light indicates that the battery is charging.
6.
When your battery pack becomes 80% charged, the red light will stay on and the green light will flash. When battery pack is fully
charged, the red light will turn off and the green light will turn on.
7.
After normal usage, 1 hour of charge time is required to be fully charged. A maximum charge time of 1 hour or less is required to
recharge a completely discharged battery pack.
8.
The battery pack will become slightly warm to the touch while charging. This is normal and does not indicate a problem.
The battery pack houses 4 colored LED lights. These LEDs indicate the state of charge and possible problems inside the battery pack.
Battery Pack
Mode
Inserted?
Standby/Power
Standby Full
Charging
Fully Charged
Evaluating
*Temp Delay
Defective
Press raised red button on battery pack to check charge:
• Red Flashing = 0-15% Charge
• Red On = 16-25% Charge
• Red and Orange On = 26-50% Charge
• Red, Orange, and Green On = 51-75% Charge
• All On = 76-100% Charge
Tips for maintaining maximum battery life:
• Charge the battery pack before it is completely discharged.
• Always stop tool operation and charge the battery when you notice less tool power.
• Never recharge a fully charged battery.
• Overcharging shortens the battery service life.

CHARGER SYMBOLS

SYMBOL
Power
No
Fade
Yes
Fade
Yes
Solid Green
Yes
Fading Green
Yes
Solid Green
Yes
Solid Green
Yes
Solid Green
Figure 2 - Battery Charge Level Lights
SIGNAL
Double Insulated Class II
CAUTION: High Voltage
Time Delay Fuse
Charging/Full
Condition
x
x
Fade
Ready for Use
Flashing Green
<80%
Fading Green
100%
x
Measuring
x
Hot/Cold
x
Damaged
14
Evaluate
Temp. Delay
x
x
x
x
x
x
x
x
Flash Orange
x
x
Flash Orange
x
x
Error
x
x
x
x
x
x
Solid Red

Publicidad

Tabla de contenido
loading

Tabla de contenido