Kohler TOUCHLESS K-13670 Instrucciones De Instalación página 6

Grifo de lavabo activado por pilas
Ocultar thumbs Ver también para TOUCHLESS K-13670:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Fig. #9. Install 4 D-Cell alkaline batteries (provided) as
shown. Note polarity as shown on battery holder. Be
sure battery lead is connected securely to circuit board.
Turn on water supplies. Test faucet by placing object
under spout in front of sensor, faucet should turn on.
Faucet should turn off after object is removed.
Fig. #10. On touchless faucets equipped with
vandal-proof aerators, use the key provided to remove
or install the aerator.
3. TROUBLESHOOTING
The faucet works properly, if the following conditions
occur during the first 10 minutes after power up.
NOTE: To see the sensors you must remove the
cover of the control box.
S
The GREEN LED is on constantly and the
faucet is running when the faucet sensor sees
an object.
S
If the faucet senses an object for more than 30
seconds, the faucet stops flushing and the
GREEN LED flashes until the object has been
removed.
If the faucet does not turn on:
S
Check the batteries for a charge and proper
installation. Replace if necessary.
S
Make sure battery pack lead wires and faucet
are plugged into circuit board.
S
Check that supply lines are open.
B
1007012-2-
Battery Lead
Connection
Circuit
Board
Fig. #10
Red LED
Faucet Lead
Connection
Circuit
Board
Fig. #11
6
Fig. #9
Straight Connector
Green LED
Electrical
Tubing
Kohler Co., Kohler, WI U.S.A.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Touchless k-13672Touchless k-13674Touchless k-13676

Tabla de contenido