GUIDANCE AND MANUFACTURER'S DECLARATION – ELECTROMAGNETIC EMISSIONS
f
f
The Body Beautiful is intended for use in the electromagnetic environment specified below. The customer or the user of
the Body Beautiful should assure that it is used in such an environment.
EMISSIONS
COMPLIANCE
RF emissions
CISPR 11
RF emissions
CISPR 11
Harmonic emissions
IEC 61000-3-2
Voltage fluctuations/ flicker
emissions
IEC 61000-3-3
The Body Beautiful is intended for use in the electromagnetic environment specified below. The customer or the user of
the Body Beautiful should assure that it is used in such an environment.
IMMUNITY
IEC 60601 TEST LEVEL
TEST
Electrostatic
±6 kV contact
discharge (ESD)
IEC 61000-4-2
±8 kV air
Electrical fast
transient/burst
±2 kV for power supply lines
IEC 61000-4-4
Surge
±1 kV line(s) and neutral
IEC 61000-4-5
<5 % U
(>95 % dip in U
T
for 0,5 cycle
Voltage
dips, short
40 % U
(60 % dip in U
interruptions
T
for 5 cycles
and voltage
variations
70 % U
(30 % dip in U
on power supply
T
for 25 cycles
input lines
IEC 61000-4-11
<5 % U
(>95 % dip in U
T
for 5s
Power frequency
(50/60 Hz)
3 A/m
magnetic field
IEC 61000-4-8
ELECTROMAGNETIC ENVIRONMENT - GUIDANCE
The Body Beautiful uses RF energy only for its internal function. Therefore, its
Group 1
RF emissions are very low and are not likely to cause any interference in nearby
Class B
Conform
The Body Beautiful is suitable for use in all establishments, including domestic
Class A
establishments and those directly connected to the public low-voltage power
supply network that supplies buildings used for domestic purposes.
Conform
GUIDANCE AND MANUFACTURER'S DECLARATION
f
f
ELECTROMAGNETIC IMMUNITY
COMPLIANCE LEVEL
±6 kV contact
±8 kV air
Not applicable
Not applicable
)
T
Not applicable
)
T
Not applicable
)
T
Not applicable
)
T
Not applicable
3A/m
NOTE - U
is the a.c. mains voltage prior to application of the test level
T
electronic equipment.
ELECTROMAGNETIC
ENVIRONMENT - GUIDANCE
Floors should be wood, concrete or ceramic tile.
If floors are covered with synthetic material, the
relative humidity should be at least 30 %.
Mains power quality should be that of a typical
commercial or hospital environment.
Mains power quality should be that of a typical
commercial or hospital environment. If a dips or an
interruption of mains power occurs, the current of
the Body Beautiful may be dropped off from normal
level, it may be necessary to use uninterruptible
power supply or a battery
Power frequency magnetic fields should be at
levels characteristic of a typical location in a typical
commercial or hospital environment.