During the auto-test all the indicators are lit during ½ second.
If an internal defect in the device is detected, all the pictograms flash in green and the device stops. Then, return the device to After Sales
Service.
The auto-test does not take into account the detection of the used batteries. When batteries are used, the auto-test is not activated.
A long press (of more than 3 seconds) involves the release of the auto-test. In this case stop the device, please, by pressing the «
and then make a short press on the «
STEP 2 - PROGRAM SELECTION KEY « P »
To select a program, make one or more short presses on the «
The programs are announced by pictograms.
As soon as a program is selected, corresponding pictogram lights.
Once the program is chosen, you can start it by increasing the power on one of power keys «
P
During the program the «
» key is inactive.
STEP 3 - END OF THE PROGRAM - STOP DURING THE PROGRAM
At the end of the session the device stops automatically.
To stop the device during the program, put the 2 power keys back on zero or press the «
STEP 4 - ADJUSTMENT OF THE POWER
The power is divided into 10 levels : 5 green, 3 orange and 2 red levels.
To change the level press the «
You have 72 levels to regulate the power from 0 to 72.
STEP 5 - BATTERIES
If the batteries are good, there is no blinking.
If the batteries are weak, two orange indicators blink. Your device still functions.
If the batteries are used, two red indicators blink. Your device stops, even in the course of a program. Change the batteries.
STEP 6 - DISCONNECTION
Your device is equipped with a detector of electrodes disconnection.
If the contact between the human body and a single electrode is absent, the power is stopped on the concerned channel. You are
warned of a disconnection by blinking of green indicator during 30 seconds.
If none of the electrodes is in contact with the body, the power cannot be emitted.
III. GENERAL INSTRUCTIONS
A. USING THE DEVICE WITH THE ELECTRODES
This function allows you to use the adhesive electrodes by connecting them directly to the modules.
You can use the device with 1 or 2 modules.
GETTING STARTED
Connect each module to the unit by matching the color indicators (photo A page 4).
f
f
Fix the electrodes to the module(s) using the snap fasteners (photo B page 4)
f
f
POSITIONING OF THE ELECTRODES
Remove the plastic backing sheet from the electrodes (photos C page 4). Moisten them by spreading a drop of water onto the
f
f
adhesive gel using your fingertips and wait 2 minutes.
Position the electrode(s) onto your body.
f
f
NB : The electrodes are for personal use. For hygiene reasons, they must always be used by the same person.
STARTING THE PROGRAM
Start your device by following the « Starting the device » procedure (chapter II).
Contractions should be firm but must never cause any pain. If the electrodes cause you any discomfort : reduce the power levels, move
the electrode(s) and then gradually increase the power. Also ensure that the electrodes are sufficiently moistened.
Now that the settings have been optimized, let your device get to work for the full duration of the program.
18
» key.
P
» key, the programs scroll.
» key. Press 1 for both the bearing from 0 to 1, then 8 consecutive presses to the following power levels.
».
» key.
» key