Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 64
- a high-density polyurethane foam insulation (CFC-free) which reduces the heat losses
caused by dispersal into the environment;
- an electrical heating assembly formed by a copper heating element;
- a temperature adjustment thermostat and overheating safety device;
- a hydraulic safety valve (pressure safety with non-return).
This appliance complies with the provisions set forth in the EEC/89/336 EMC directive
relating to electromagnetic compatibility.

Technical data

Model
Capacity
Tension
Power
Weight
Water pressure
Installation regulations (for the installer)
Installation and dimensions diagram (fig. 1).
WARNING! Adhere strictly to the general warnings and the safety regulations listed at
!
the beginning of the text and follow all the instructions provided under all circumstances.
The installation, set-up, maintenance and possible replacement of the water heater
must be performed by qualified personnel in compliance with all applicable regulations
and with any provisions set forth by local authorities and public health organisations.
Before performing any maintenance work and/or replacing any parts, make sure that the
appliance is switched off.
The appliance heats water to a temperature below boiling point.
It must be connected to a domestic water mains supply, established in accordance with
the performance levels and capacity of the appliance.
Before connecting the appliance, it is first necessary to:
- check whether the features (please refer to the data plate) meet the customer's
requirements;
- make sure the installation conforms with the IP degree (of protection against the
penetration of liquids) of the appliance in accordance with all current applicable
regulations.
- read the information provided on the packaging label and on the appliance data plate.
In the event of walls created using bricks or perforated blocks, partition walls featuring
limited immobility, or any masonry which is in some way different from the types listed, it
will first be necessary to carry out a preliminary immobility test on the support system.
The wall-mounting fastening hooks must be capable of supporting a total weight which
is three times the weight of the water heater when it is filled with water. Fastening hooks
with a diameter of at least 10 mm are recommended.
Local regulations could place restrictions on installation within a bathroom environment.
The minimum distances set out by all current applicable regulations should therefore be
respected.
The appliance (A fig. 2) should be installed as close as possible to the points of use in
order to limit heat dispersion along the piping.
120
l.
120
V
W
2000
Kg.
35
bar
150
200
150
200
230
2200
2600
41
51
8
GB
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ti 120/lSg 120Sg 150Ti 200/lTi 150/l

Tabla de contenido