TecMate Optimate TM270 Modo De Empleo página 7

Cargador automático
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 17
STEP 2
LED #1a or #1b &
LED #3 flash
Protection
together
Voltage
Error
1a
Charger
will not
12.8V
proceed
without
user
interaction!
STEP 3
Battery SOC check
Preparing
1a
1b
to charge
2
12.8V
16V
12.8V
Temp° chec
STEP
LED #3 : RED
4
4, 5 & 6
SAVE
3
State Of
Bms
Bms
Time to save a
Charge:
battery
Less than
LFP
50%
12.8V
12 34
STEP 4
LiFePO
V < 8.8V
(16V: V < 11V)
STEP 5
8.8V ≤ V ≤ 13.1V
(16V: 11V ≤ V ≤ 16.3V)
STEP 6
TEST cell damage
The battery is deep discharged OR the battery voltage does not match
the selected voltage. (Battery voltage is lower or higher than is
considered normal).
1. Confirm battery's nominal voltage matches the selected voltage.
If not, disconnect charger from battery. Select correct voltage.
1b
2
Reconnect battery to charger.
If it matches the selected voltage (16V), go to point 2 below.
16V
2. For a deep discharged 16V battery (16V selected): Push and
hold button for at least 3 seconds until LED #1a / #1b and LED #3
5
turn full on.
4
The program automatically proceeds to STEP3.
3. Release pushbutton.
3
Immediately following connection to a battery there may be a 1-2
second delay before charging progresses, during which time:
Bms
Bms
Battery State Of Charge is measured to determine charge requirement
6
7
and duration of the State Of Health test in STEP 9. A low battery will be
8
tested for 12 hours.
LFP
safeTº: Ambient temperature is measured to determine safe charge
12 34
k
LiFePO
current parameters. See page 2 for temperature (°C/°F) and
4
5
corresponding Ampére (A) values.
optimate1.com
The battery SAVE mode engages if the battery is less than 50%
/oml12.8v16v
/oml12.8v16v
charged OR voltage is between 0.5 to 13.1 Volt (16V: 0.5V <> 16.3V)
IMPORTANT: Read the section VERY FLAT NEGLECTED BATTERIES on
the preceding page.
A very flat battery should progress to STEP 7 within 4 hours, unless
damage has been detected, then charging will be suspended and TEST
LED #8 (red) will flash rapidly, indicating the battery may have suffered
permanent damage or a professional assessment is required.
16V
12 345
VERY LOW VOLTAGE SAVE : Current starts at 600mA and will
4
increase to 1.25A depending on charge progress. If the voltage did not
rise above 8.8V (16V: 11V) within 2 hours, charging will be suspended
and the TEST LED #8 (red) will flash, indicating the battery may have
suffered permanent damage or a professional assessment is required.
LOW VOLTAGE SAVE :
Charge current is increased to 2.5A*. The battery's charge acceptance
is monitored for unusual behaviour.
*Charge current is increased to 6A following a BMS reset.
A deep discharged battery that may not hold sufficient voltage to
power its own BMS system will automatically receive repeated BMS
reset pulses during SAVE mode so that charging may continue. If
charging did not continue, use the MANUAL CHARGE ACTIVATION mode
described under STEP 1.
TESTING (2 min) - The battery's ability to hold charge is monitored. A
healthy LiFePO
will be suspended and TEST LED #8 (red) will flash rapidly, indicating
the battery may have suffered permanent damage or a professional
assessment is required.
24-7
24-7
6
7
8
optimate1.com
/oml12.8v16v
/oml12.8v16v
24-7
24-7
16V
12 345
battery will progress to STEP 7, otherwise charging
4
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Optimate tm271Optimate tm272

Tabla de contenido