3. After connecting the power cord to the machine, make
certain the rotation of the motor is in the proper direc-
tion by viewing the rotation of the blower fan. The
fan should rotate in a clockwise direction. Rotation
of the motor can be reversed by interchanging any
two of the three incoming power lines connected to
terminals (C) Fig. 15.
BE SURE TO DISCONNECT MACHINE AT
POWER SOURCE BEFORE REVERSING WIRES.
460 VOLT OPERATION
460V operation of the 50-764 requires replacement of the
motor starter and reconfiguration of the motor's internal
connections. This item is available from most industrial
electrical supply dealers and must be installed by a
qualified electrician.
DO NOT ATTEMPT TO WIRE THE MACHINE
FOR 460 VOLTS WITHOUT REPLACING THE STARTER.
DOING SO WILL CAUSE DAMAGE TO THE MACHINE
AND PERSONAL INJURY COULD RESULT.
MODEL 50-765 SINGLE
PHASE INSTALLATION
Your dust collector is supplied with a motor and a mag-
netic starter controller and must be permanently con-
nected to the building's electrical system and grounded
to meet code.
1. To connect the dust collector to a power system, re-
move controller cover (A) Fig. 14.
2. Bring the single phase power line through the access
hole (B) Fig. 14, in the top of controller box and con-
nect the two power lines to terminals (E) Fig. 16, and
the green ground wire to ground screw (F).
BE SURE TO REINSTALL COVER BE-
FORE OPERATING.
DO NOT INSERT FINGERS OR ANY
FOREIGN OBJECT INTO THE DUST
INTAKE PORT.
FOR OPERATOR SAFETY, DO NOT OPERATE THE MACHINE WITH ANY DUST INTAKE HOLES
UNCOVERED. THE ROTATING FAN LOCATED INSIDE THE BLOWER HOUSING IS ACCESSIBLE
THROUGH THE DUST IN-TAKE PORT AND CAN BE HAZARDOUS. ALWAYS WEAR PROPER APPAREL. DO NOT
WEAR JEWELRY AND KEEP FINGERS AND ALL FOREIGN OBJECTS OUT OF THE DUST INTAKE PORT. FOLLOW
THE SAFETY RULES IN THIS MANUAL.
STARTING AND STOPPING DUST
COLLECTOR
1. The on (A) and off (B) buttons are located on the front
of the motor housing as shown in Fig. 17. To turn the
machine "ON", push the "ON" button (A).
2. To turn the machine "OFF", push the off button (B).
D

OPERATION

Model 50-764
B
A
14
C
Fig. 15
E
Fig. 16
MAKE SURE UNIT IS PROPERLY
GROUNDED.
Model 50-765
B
A
Fig. 17