ELM4L & ELM6L
EMERGENCY LIGHTING UNIT
Installation and wiring ................................................................................... P. 2-3
Testing and maintenance ..............................................................................P. 4-5
NOTE: Product versions that are certified in the CA Title 20 Appliance Efficiency Database are marked
BC on the product label.
!
WARNING:
FAILURE TO FOLLOW THESE INSTRUCTIONS AND WARNINGS MAY RESULT IN DEATH, SERIOUS INJURY OR
SIGNIFICANT PROPERTY DAMAGE
maintaining this equipment. These instructions do not attempt to cover all installation and maintenance situations. If you do not understand
these instructions or additional information is required, contact Holophane.
!
WARNING: RISK OF ELECTRIC SHOCK – NEVER CONNECT TO, DISCONNECT FROM OR SERVICE WHILE EQUIPMENT IS
!
ENERGIZED
.
WARNING:
DO NOT USE ABRASIVE MATERIALS OR SOLVENTS. USE OF THESE SUBSTANCES MAY DAMAGE FIXTURE,
WHICH MAY RESULT IN PERSONAL INJURY.
!
WARNING
: RISK OF PERSONAL INJURY – This product may have sharp edges. Wear gloves to prevent cuts or abrasions when removing
!
from carton, handling, installing and maintaining this product.
WARNING:
The battery used in this device may present a risk of fire or chemical burn if mistreated. Temperature range 50°F -104°F (10°C -40°C).
Do not disassemble, heat above 70°C (158°F), or incinerate. Replace battery only as directed on the battery label and page 5 of these instructions.
Use of unauthorized battery voids warranty and UL listing of this product and may present a risk of fire or explosion.
•Disconnect A.C. power before servicing.
•All servicing should be performed by qualified personnel.
•Consult your local building code for approved wiring and installation.
•Do not use outdoors unless used with Acuity Brands accessories appropriate to the application.
•Do not mount near gas or electric heater.
•Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
•The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
•Do not use this equipment for other than intended use.
AND DELIVER TO OWNER AFTER INSTALLATION
Remote test option
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions
should always be followed, including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
- For your protection, read and follow these warnings and instructions carefully before installing or
SAVE THESE INSTRUCTIONS
"TEST" button / Status I
ndicator
Press latches to disengage
housing from mounting plate

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Acuity Brands Lithonia Lighting Quantum ELM4L

  • Página 1 •All servicing should be performed by qualified personnel. •Consult your local building code for approved wiring and installation. •Do not use outdoors unless used with Acuity Brands accessories appropriate to the application. •Do not mount near gas or electric heater.
  • Página 2 INSTALLATION and WIRING page 2 IMPORTANT: Provide each unit with a single-phase AC un-switched power supply from a circuit used for normal lighting. Operating voltage shown on table on page 3. NOTE: The battery must be connected to the charger board prior to applying AC power to the unit. Battery damage may occur if the battery is connected longer than 24 hours without continuous AC power provided.
  • Página 3: Final Assembly

    INSTALLATION and WIRING (CONTINUED) page 3 FINAL ASSEMBLY Federal Communications Connect the polarized battery plug to Housing attachment to mounting plate: Commission (FCC) Requirements: the charger board. Make certain that Make certain all wires and connectors are This device complies with FCC Title the battery cable is routed to avoid routed to avoid interference with other 47, Part 15, Subpart B.
  • Página 4 TESTING and MAINTENANCE page 4 IMPORTANT BATTERY INFORMATION: NOTE: Emergency lighting systems should be tested in Batteries are perishable items. For best results, it is accordance with NFPA 101 or as often as local codes recommended that the batteries receive an initial charge within require, to ascertain that all components are operational.
  • Página 5: Battery Replacement

    TESTING and MAINTENANCE page 5 BATTERY REPLACEMENT Unit features and battery details shown may vary. See also “Battery Connection”, page 3. Disconnect battery from charger board. Replace battery, secure the strap Re-assemble the unit (see also snugly, and reconnect to the charger step 5, page 3).
  • Página 6 Then re- assemble the unit (see also step 5, page 3). Part # 912-00027-101 Rev. E, 10/2020 LIFE SAFETY SOLUTIONS 800-705-SERV (7378) © Acuity Brands Lighting, Inc. 2020 techsupport-emergency@acuitybrands.com All Rights Reserved. www.lithonia.com...
  • Página 7: Medidas De Seguridad Importantes

    •Consulte su código local de edificación para conocer los tipos de cableado e instalación aprobados. •No utilice el aparato al aire libre, a menos que se utilice con los accesorios Acuity Brands apropiados para la aplicación. •No haga instalaciones cerca de calefactores eléctricos o a gas.
  • Página 8: Montaje De La Caja De Unión

    INSTALACIÓN y CABLEADO página 2 IMPORTANTE: Proporcione a cada unidad una fuente de CA no conmutada monofásica de un circuito utilizado para la iluminación normal. El voltaje de funcionamiento se muestra en la tabla de la página 3. NOTA: La batería debe estar conectada a la placa del cargador antes de aplicar la alimentación de CA a la unidad. La batería puede dañarse si permanece conectada durante más de 24 horas sin alimentación de CA continua.
  • Página 9: Montaje Final

    INSTALACIÓN Y CABLEADO (CONTINUACIÓN) página 3 MONTAJE FINAL Requisitos de la Comisión Federal Conecte el enchufe de la batería Accesorios de la carcasa para la placa de de Comunicaciones (FCC): polarizado a la placa del cargador. montaje: Asegúrese de que todos los cables y los conectores Este dispositivo cumple con el Título Asegúrese de verificar el recorrido del sigan una ruta para evitar la interferencia con otros...
  • Página 10 PRUEBA y MANTENIMIENTO página 4 NOTA: Los sistemas de iluminación de emergencia deben ser INFORMACIÓN IMPORTANTE SOBRE LAS BATERÍAS: probados de acuerdo con la norma NFPA 101 o con la Las baterías son productos perecederos. Para obtener mejores regularidad que exijan los códigos locales, para verificar que resultados, se recomienda que las baterías reciban una carga inicial todos los componentes sean operativos.
  • Página 11: Reemplazo De La Batería

    PRUEBA y MANTENIMIENTO página 5 REEMPLAZO DE LA BATERÍA: Las características de la unidad y los detalles de la batería que se muestran pueden variar. Vea también “Conexiones de batería” en la página 3. Desconecte la batería del cargador Reemplace la batería, asegure bien la Vuelva a ensamblar la unidad (consulte cinta y vuelva a conectarla a la placa también el paso 5 en la página 3).
  • Página 12: Mantenimiento

    Luego vuelva a ensamblar la unidad (consulte también el paso 5, página 3). SOLUCIONES DE SEGURIDAD PERSONAL N.º de pieza: 912-00027-101 Rev. E, 10/2020 800-705-SERV (7378) techsupport-emergency@acuitybrands.com www.lithonia.com © Acuity Brands Lighting, Inc. 2020 Todos los derechos reservados.