Definitions Of Measurement Parameters; Range Configuration - Textron GREENLEE 920XC-13A Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

920XC-13A • 920XC-15A • 920XC-20C Instruction Manual
All manuals and user guides at all-guides.com

Definitions of Measurement Parameters

Parameter
Range
Pulse.Width
Average Time
Wavelength
Measurement.Mode
VFL
Length Units
IOR
Scatter Coefficient
Non-reflection
Threshold
Reflection Threshold
End Threshold
Delete.File
Time
Auto.Off
Lang./
LCD Contrast
Color Mode
Load Default
Help

Range Configuration

Generally, the range is set according to the actual length of optical fiber in order to insure the
accuracy.of.the.measurement.
Under the parameter configuration menu use p.and.q to highlight "Range." Press Enter.to.select.
a range (Figure 3-10). Press
Use.p.and.q to select an adequate range. Press Enter to confirm.
Length of optical fiber relevant to the trace
Width of laser pulse sent out from OTDR to optical fiber
Select.suitable.testing.time
Select laser wavelength for measurement
Select.mode.for.measurement
Power on or off for visible laser
Select.units.of.measurement
IOR of optical fiber which affects the transmission speed of laser
Affects backscatter power of laser in fiber
Events whose insertion loss is > the threshold displayed here
Reflection events ≥ the threshold displayed here
First event with insertion loss ≥ the threshold is considered the end of
fiber, and all following events will be ignored
Delete.stored.trace.data.in.the.instrument
Show.current.system.time
Enable or disable auto off function
Choose language
Adjust contrast of LCD
Select.suitable.color.setting.for.display
Set.all.parameters.to.factory.setting
Show Help files (quick reference)
.to.exit.
Figure 3-10. Range Configuration
Basic OTDR Information
Definition
21

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Greenlee 920xc-15aGreenlee 920xc-20с

Tabla de contenido