Scatter Coefficient Configuration
Scatter coefficient determines the value of backscatter power. This configuration affects the
calculation of reflection value.
Under the parameter configuration menu use p.and.q to highlight "Scat. Coef." Press Enter.to.
enter a value (Figure 3-18). Press
Figure 3-18. Scatter Coefficient Configuration
Use.t.and.u to adjust the position of the highlighted area. Use p.and.q.to.change.the.digits..
After.setting,.press.Enter to confirm.
Non-reflection Threshold Configuration
This configuration has direct impact on the listing of insertion loss events. Only events ≥ to this
threshold.will.be.listed.
Under the parameter configuration menu use p.and.q to highlight "Nrefl. Thre." Press Enter.to.
enter a value (Figure 3-19). Press
Figure 3-19. Non-reflection Threshold Configuration
Use.t.and.u to adjust the position of the highlighted area. Use p.and.q.to.change.the.digits..
After.setting,.press.Enter to confirm.
Note: The default setting is "0.20 dB."