MODELS IN THE P200BENC

MODELOS DE LA SERIE P200BENC

Pull the terminal board out of its housing, as shown in
Fig. A and observe how the wires are connected in order
as shown in Fig. B:
Wires of the photodiode encoder card: white, brown, blue (0.5 mm² cross section);
2
Motor phase wires: black, red (2.5 mm
cross section);
The encoder's signal wires are to be connected to the MEC20 card connectors in the following way: brown - terminal 21,
st
blue - terminal 22, white 1st motor - terminal 23, white 2nd motor - terminal 24.Connect the black and red wires of the 1
motor to terminals 7 and 8 and to terminals 9 and 10 those of the 2nd motor. Check that the required maneuver
corresponds to an opening input; to the contrary, reverse the position of the black-red wires.It is essential that the cross
section of the wires must be identical for connecting to the command card.
Extraiga el tablero de bornes de su alojamiento, como muestra la figura A y observe con atención el orden en el cual
están conectados los cables, como muestra la figura B:
Cables de la tarjeta encóder fotodiodo: blanco, marrón y azul (secc. 0,5 mm²);
Cables de la fase del motor: negro y rojo (secc. 2,5 mm²);
Los cables de señal del encóder se conectan a los conectores de la tarjeta MEC20 de la siguiente manera: marrón – borne 21,
azul - borne 22, blanco 1er. motor - borne 23, blanco 2do. motor - borne 24.Conecte los cables negro y rojo del 1er. motor a los
bornes 7-8 y los del 2do. motor a los bornes 9-10. Controle que a un input de apertura corresponda la maniobra deseada; en
caso contrario invierta la posición de los cables negro y rojo.Para las conexiones a la tarjeta de comando, use únicamente
cables con la misma sección.
MODELS IN THE P2000 SERIES

MODELOS DE LA SERIE P2000

1) Connect up to the terminal of Fig. A with a wire whose cross section should at least be equal to 1.5 mm², checking motor
rotation direction and remembering that:
The yellow-green wire is the earth wire
Blue is the common wire
Black is the phase wire
And brown is the phase wire.
2) Connect the capacitor provided in parallel with the motor's two phases in proximity of the electronic control card. Only use
units equipped with an electric friction.
1) Conectarse al borne de la Fig. 18 con cables que tengan una sección de al menos 1.5 mm², comprobando el sentido de
rotación del motor, recordando que:
Cable amarillo-verde : tierra
Cable azul : común
Cable negro : fase
Cable marrón : fase
2) Cerca de la placa electrónica, conectar el condensador en equipamiento, en paralelo a las 2 fases del motor. Utilizar
exclusivamente centralitas dotadas de embrague eléctrico.